» Articles » PMID: 36081075

Intra-Rater Reliability of Shear Wave Elastography for the Quantification of Respiratory Muscles in Adolescent Athletes

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2022 Sep 9
PMID 36081075
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study was to assess the intra-rater reliability and agreement of diaphragm and intercostal muscle elasticity and thickness during tidal breathing. The diaphragm and intercostal muscle parameters were measured using shear wave elastography in adolescent athletes. To calculate intra-rater reliability, intraclass correlation coefficient (ICC) and Bland-Altman statistics were used. The reliability/agreement for one-day both muscle measurements (regardless of probe orientation) were at least moderate. During the seven-day interval between measurements, the reliability of a single measurement depended on the measured parameter, transducer orientation, respiratory phase, and muscle. Excellent reliability was found for diaphragm shear modulus at the peak of tidal expiration in transverse probe position (ICC = 0.91-0.96; ICC. = 0.95), and from poor to excellent reliability for the intercostal muscle thickness at the peak of tidal inspiration with the longitudinal probe position (ICC = 0.26-0.95; ICC. = 0.15). The overall reliability/agreement of the analysed data was higher for the diaphragm measurements (than the intercostal muscles) regardless of the respiratory phase and probe position. It is difficult to identify a more appropriate probe position to examine these muscles. The shear modulus/thickness of the diaphragm and intercostal muscles demonstrated good reliability/agreement so this appears to be a promising technique for their examination in athletes.

Citing Articles

Advancements in imaging techniques for monitoring the respiratory muscles.

Dres M, Doorduin J, Boussouar S, Bachasson D Crit Care. 2025; 29(1):110.

PMID: 40075482 PMC: 11905469. DOI: 10.1186/s13054-025-05339-1.


Upper extremity soft tissue stiffness measured with shear wave elastography: A between-day reliability study.

Day J, Merriman H Shoulder Elbow. 2024; 16(2):159-168.

PMID: 38655409 PMC: 11034466. DOI: 10.1177/17585732231179115.


Editorial for the Special Issue "Sensing-Based Biomedical Communication and Intelligent Identification for Healthcare".

Jia W, Gao Y, Mao Z, Sun M Sensors (Basel). 2024; 24(5).

PMID: 38474939 PMC: 10934641. DOI: 10.3390/s24051403.


Relationship between respiratory muscles ultrasound parameters and running tests performance in adolescent football players. A pilot study.

Palac M, Sikora D, Wolny T, Linek P PeerJ. 2023; 11:e15214.

PMID: 37090113 PMC: 10117394. DOI: 10.7717/peerj.15214.

References
1.
Gursel G, Inci K, Alasgarova Z . Can Diaphragm Dysfunction Be Reliably Evaluated with Pocket-Sized Ultrasound Devices in Intensive Care Unit?. Crit Care Res Pract. 2018; 2018:5192647. PMC: 5902116. DOI: 10.1155/2018/5192647. View

2.
Chino K, Ohya T, Katayama K, Suzuki Y . Diaphragmatic shear modulus at various submaximal inspiratory mouth pressure levels. Respir Physiol Neurobiol. 2018; 252-253:52-57. DOI: 10.1016/j.resp.2018.03.009. View

3.
Palac M, Rutka M, Wolny T, Podgorski M, Linek P . Ultrasonography in Assessment of Respiratory Muscles Function: A Systematic Review. Respiration. 2022; 101(9):878-892. DOI: 10.1159/000524785. View

4.
Poulard T, Dres M, Nierat M, Rivals I, Hogrel J, Similowski T . Ultrafast ultrasound coupled with cervical magnetic stimulation for non-invasive and non-volitional assessment of diaphragm contractility. J Physiol. 2020; 598(24):5627-5638. DOI: 10.1113/JP280457. View

5.
Mikolajowski G, Palac M, Wolny T, Linek P . Lateral Abdominal Muscles Shear Modulus and Thickness Measurements under Controlled Ultrasound Probe Compression by External Force Sensor: A Comparison and Reliability Study. Sensors (Basel). 2021; 21(12). PMC: 8230760. DOI: 10.3390/s21124036. View