Lateral Abdominal Muscles Shear Modulus and Thickness Measurements Under Controlled Ultrasound Probe Compression by External Force Sensor: A Comparison and Reliability Study

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2021 Jul 2
PMID 34208168
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of this study was to perform a reliability and agreement analysis and to compare lateral abdominal muscles (LAMs) thickness and elasticity results obtained by an experienced operator, by a non-experienced operator, and in an ultrasound imaging probe compression controlled (PCC) condition with minimal force necessary to obtain a proper ultrasound image. The sample consisted of 39 adolescents. An Aixplorer ultrasound scanner was used to evaluate the LAM. The probe in PCC condition was positioned in a prepared probe holder coupled with a pressure sensor. The LAM thickness and elasticity measurements were significantly ( < 0.05) different in the ultrasound PCC condition, compared to results obtained by both examiners. The abdominal oblique external and internal muscle thickness measurements were underestimated and all LAM shear moduli were overestimated during measurements without controlling the probe compression by an external sensor. The intra-class correlation coefficient was excellent in all conditions, but the smallest detectable differences were approximately 43-60% lower during the measurements collected in PCC condition. Differences in LAM measurements between PCC and 'on-hand' conditions may be clinically irrelevant when the force applied by the probe is consciously controlled by the examiner. However, during ultrasound measurements of the LAM morphology, the potential under/over estimation should always be considered when measurements are performed without controlling probe compression by an external sensor.

Citing Articles

Water immersion ultrasound can improve the repeatability of ultrasonic measurement of dorsalis pedis artery diameter and hemodynamic parameters.

Zhang Z, Xu Y, Hao Z, Wang H Ir J Med Sci. 2023; 193(2):987-991.

PMID: 37707689 DOI: 10.1007/s11845-023-03522-3.


Ultrasonic Imaging and Sensors.

Camacho J, Svilainis L, Alvarez-Arenas T Sensors (Basel). 2022; 22(20).

PMID: 36298262 PMC: 9611746. DOI: 10.3390/s22207911.


Intra-Rater Reliability of Shear Wave Elastography for the Quantification of Respiratory Muscles in Adolescent Athletes.

Palac M, Linek P Sensors (Basel). 2022; 22(17).

PMID: 36081075 PMC: 9460867. DOI: 10.3390/s22176622.


Quantitative Analysis of Abdominal Muscles Using Elastography in Female Patients With Incisional Hernia.

Wang B, He K, Zhu Y, Fu X, Yao Q, Chen H Front Surg. 2022; 9:831184.

PMID: 35495759 PMC: 9039235. DOI: 10.3389/fsurg.2022.831184.


Feasibility of Using a Portable MyotonPRO Device to Quantify the Elastic Properties of Skeletal Muscle.

Li Y, Liu C, Zhang Z Med Sci Monit. 2022; 28:e934121.

PMID: 35087016 PMC: 8805342. DOI: 10.12659/MSM.934121.


References
1.
ShahAli PT PhD S, Arab PT PhD A, Ebrahimi PT PhD E, ShahAli MD S, Rahmani PT PhD N, Negahban PT PhD H . Ultrasound measurement of abdominal muscles during clinical isometric endurance tests in women with and without low back pain. Physiother Theory Pract. 2018; 35(2):130-138. DOI: 10.1080/09593985.2018.1441345. View

2.
Browne J, Watson A, Hoskins P, Elliott A . Investigation of the effect of subcutaneous fat on image quality performance of 2D conventional imaging and tissue harmonic imaging. Ultrasound Med Biol. 2005; 31(7):957-64. DOI: 10.1016/j.ultrasmedbio.2005.03.012. View

3.
Linek P, Wolny T, Sikora D, Klepek A . Supersonic Shear Imaging for Quantification of Lateral Abdominal Muscle Shear Modulus in Pediatric Population with Scoliosis: A Reliability and Agreement Study. Ultrasound Med Biol. 2019; 45(7):1551-1561. DOI: 10.1016/j.ultrasmedbio.2019.03.001. View

4.
Mannion A, Pulkovski N, Toma V, Sprott H . Abdominal muscle size and symmetry at rest and during abdominal hollowing exercises in healthy control subjects. J Anat. 2009; 213(2):173-82. PMC: 2526114. DOI: 10.1111/j.1469-7580.2008.00946.x. View

5.
Kim D, Kim C, Lee B, Seo D . A comparison of ultrasonography measurement on the abdominal muscle thickness between adolescent idiopathic scoliosis and healthy subjects. J Back Musculoskelet Rehabil. 2017; 31(1):65-74. DOI: 10.3233/BMR-169667. View