» Articles » PMID: 36044602

Using Spectroscopy to Guide the Adaptation of Aptamers into Electrochemical Aptamer-Based Sensors

Overview
Journal Bioconjug Chem
Specialty Biochemistry
Date 2022 Aug 31
PMID 36044602
Authors
Affiliations
Soon will be listed here.
Abstract

Electrochemical aptamer-based (EAB) sensors utilize the binding-induced conformational change of an electrode-attached, redox-reporter-modified aptamer to transduce target recognition into an easily measurable electrochemical output. Because this signal transduction mechanism is single-step and rapidly reversible, EAB sensors support high-frequency, real-time molecular measurements, and because it recapitulates the reagentless, conformation-linked signaling seen in vivo among naturally occurring receptors, EAB sensors are selective enough to work in the complex, time-varying environments found in the living body. The fabrication of EAB sensors, however, requires that their target-recognizing aptamer be modified such that (1) it undergoes the necessary binding-induced conformational change and (2) that the thermodynamics of this "conformational switch" are tuned to ensure that they reflect an acceptable trade-off between affinity and signal gain. That is, even if an "as-selected" aptamer achieves useful affinity and specificity, it may fail when adapted to the EAB platform because it lacks the binding-induced conformational change required to support EAB signaling. In this paper we reveal the spectroscopy-guided approaches we use to modify aptamers such that they support the necessary binding-induced conformational change. Specifically, using newly reported aptamers, we demonstrate the systematic design of EAB sensors achieving clinically and physiologically relevant specificity, limits of detection, and dynamic range against the targets methotrexate and tryptophan.

Citing Articles

Carboxylate-Terminated Electrode Surfaces Improve the Performance of Electrochemical Aptamer-Based Sensors.

Bakestani R, Wu Y, Glahn-Martinez B, Kippin T, Plaxco K, Kolkman R ACS Appl Mater Interfaces. 2025; 17(5):8706-8714.

PMID: 39841926 PMC: 11803614. DOI: 10.1021/acsami.4c21790.


Modular DNA origami-based electrochemical detection of DNA and proteins.

Jeon B, Guareschi M, Stewart J, Wu E, Gopinath A, Arroyo-Curras N Proc Natl Acad Sci U S A. 2025; 122(1):e2311279121.

PMID: 39793064 PMC: 11725875. DOI: 10.1073/pnas.2311279121.


Effects of Physiological-Scale Variation in Cations, pH, and Temperature on the Calibration of Electrochemical Aptamer-Based Sensors.

Fetter L, McDonough M, Kippin T, Plaxco K ACS Sens. 2024; 9(12):6675-6684.

PMID: 39570094 PMC: 11855119. DOI: 10.1021/acssensors.4c02274.


Dual-Purpose Aptamer-Based Sensors for Real-Time, Multiplexable Monitoring of Metabolites in Cell Culture Media.

Yang Y, Gao X, Widdicombe B, Zhang X, Zielinski J, Cheng T ACS Nano. 2024; .

PMID: 39255458 PMC: 11441400. DOI: 10.1021/acsnano.4c06813.


Codeposition Enhances the Performance of Electrochemical Aptamer-Based Sensors.

Wu Y, Shi J, Kippin T, Plaxco K Langmuir. 2024; 40(16):8703-8710.

PMID: 38616608 PMC: 11821552. DOI: 10.1021/acs.langmuir.4c00585.


References
1.
Zadeh J, Steenberg C, Bois J, Wolfe B, Pierce M, Khan A . NUPACK: Analysis and design of nucleic acid systems. J Comput Chem. 2010; 32(1):170-3. DOI: 10.1002/jcc.21596. View

2.
Vallee-Belisle A, Ricci F, Plaxco K . Thermodynamic basis for the optimization of binding-induced biomolecular switches and structure-switching biosensors. Proc Natl Acad Sci U S A. 2009; 106(33):13802-7. PMC: 2728975. DOI: 10.1073/pnas.0904005106. View

3.
White R, Plaxco K . Exploiting binding-induced changes in probe flexibility for the optimization of electrochemical biosensors. Anal Chem. 2009; 82(1):73-6. PMC: 2802819. DOI: 10.1021/ac902595f. View

4.
Howard S, McCormick J, Pui C, Buddington R, Harvey R . Preventing and Managing Toxicities of High-Dose Methotrexate. Oncologist. 2016; 21(12):1471-1482. PMC: 5153332. DOI: 10.1634/theoncologist.2015-0164. View

5.
Renaud de la Faverie A, Guedin A, Bedrat A, Yatsunyk L, Mergny J . Thioflavin T as a fluorescence light-up probe for G4 formation. Nucleic Acids Res. 2014; 42(8):e65. PMC: 4005661. DOI: 10.1093/nar/gku111. View