» Articles » PMID: 35957991

Myths and Misconceptions of Airway Pressure Release Ventilation: Getting Past the Noise and on to the Signal

Overview
Journal Front Physiol
Date 2022 Aug 12
PMID 35957991
Authors
Affiliations
Soon will be listed here.
Abstract

In the pursuit of science, competitive ideas and debate are necessary means to attain knowledge and expose our ignorance. To quote Murray Gell-Mann (1969 Nobel Prize laureate in Physics): "Scientific orthodoxy kills truth". In mechanical ventilation, the goal is to provide the best approach to support patients with respiratory failure until the underlying disease resolves, while minimizing iatrogenic damage. This compromise characterizes the philosophy behind the concept of "lung protective" ventilation. Unfortunately, inadequacies of the current conceptual model-that focuses exclusively on a nominal value of low tidal volume and promotes shrinking of the "baby lung" - is reflected in the high mortality rate of patients with moderate and severe acute respiratory distress syndrome. These data call for exploration and investigation of competitive models evaluated thoroughly through a scientific process. Airway Pressure Release Ventilation (APRV) is one of the most studied yet controversial modes of mechanical ventilation that shows promise in experimental and clinical data. Over the last 3 decades APRV has evolved from a rescue strategy to a preemptive lung injury prevention approach with potential to stabilize the lung and restore alveolar homogeneity. However, several obstacles have so far impeded the evaluation of APRV's clinical efficacy in large, randomized trials. For instance, there is no universally accepted standardized method of setting APRV and thus, it is not established whether its effects on clinical outcomes are due to the ventilator mode or the method applied. In addition, one distinctive issue that hinders proper scientific evaluation of APRV is the ubiquitous presence of myths and misconceptions repeatedly presented in the literature. In this review we discuss some of these misleading notions and present data to advance scientific discourse around the uses and misuses of APRV in the current literature.

Citing Articles

Comparison of airway pressure release ventilation (APRV) versus biphasic positive airway pressure (BIPAP) ventilation in COVID-19 associated ARDS using transpulmonary pressure monitoring.

Stoll S, Leupold T, Drinhaus H, Dusse F, Bottiger B, Mathes A BMC Anesthesiol. 2025; 25(1):52.

PMID: 39893363 PMC: 11786409. DOI: 10.1186/s12871-025-02904-7.


Current practice of using the airway pressure release ventilation mode in acute respiratory distress syndrome patients among respiratory therapists in Saudi Arabia.

Alqarni A, Aldhahir A, Siraj R, Alasimi A, Alqahtani J, Alwafi H SAGE Open Med. 2025; 13():20503121241312941.

PMID: 39839159 PMC: 11748082. DOI: 10.1177/20503121241312941.


Awareness and practice of airway pressure release ventilation mode in acute respiratory distress syndrome patients among nurses in Saudi Arabia.

Aldhahir A, Alqarni A, Madkhali M, Madkhali H, Bakri A, Shawany M BMC Nurs. 2024; 23(1):79.

PMID: 38291421 PMC: 10826023. DOI: 10.1186/s12912-024-01763-w.


Time-Controlled Adaptive Ventilation (TCAV): a personalized strategy for lung protection.

Al-Khalisy H, Nieman G, Kollisch-Singule M, Andrews P, Camporota L, Shiber J Respir Res. 2024; 25(1):37.

PMID: 38238778 PMC: 10797864. DOI: 10.1186/s12931-023-02615-y.


Synchronized ventilation during resuscitation in pigs does not necessitate high inspiratory pressures to provide adequate oxygenation.

Renz M, Noack R, Rissel R, Mohnke K, Riedel J, Dunges B World J Emerg Med. 2023; 14(5):393-396.

PMID: 37908797 PMC: 10613795. DOI: 10.5847/wjem.j.1920-8642.2023.089.


References
1.
Myers T, MacIntyre N . Respiratory controversies in the critical care setting. Does airway pressure release ventilation offer important new advantages in mechanical ventilator support?. Respir Care. 2007; 52(4):452-8. View

2.
Smith R, Smith D . Does airway pressure release ventilation alter lung function after acute lung injury?. Chest. 1995; 107(3):805-8. DOI: 10.1378/chest.107.3.805. View

3.
Natalini G, Tuzzo D, Rosano A, Testa M, Grazioli M, Pennestri V . Assessment of Factors Related to Auto-PEEP. Respir Care. 2015; 61(2):134-41. DOI: 10.4187/respcare.04063. View

4.
Marini J, Culver B, Kirk W . Flow resistance of exhalation valves and positive end-expiratory pressure devices used in mechanical ventilation. Am Rev Respir Dis. 1985; 131(6):850-4. DOI: 10.1164/arrd.1985.131.6.850. View

5.
BERGMAN N . Measurement of respiratory resistance in anesthetized subjects. J Appl Physiol. 1966; 21(6):1913-7. DOI: 10.1152/jappl.1966.21.6.1913. View