Assessment of Factors Related to Auto-PEEP

Abstract

Background: Previous physiological studies have identified factors that are involved in auto-PEEP generation. In our study, we examined how much auto-PEEP is generated from factors that are involved in its development.

Methods: One hundred eighty-six subjects undergoing controlled mechanical ventilation with persistent expiratory flow at the beginning of each inspiration were enrolled in the study. Volume-controlled continuous mandatory ventilation with PEEP of 0 cm H2O was applied while maintaining the ventilator setting as chosen by the attending physician. End-expiratory and end-inspiratory airway occlusion maneuvers were performed to calculate respiratory mechanics, and tidal flow limitation was assessed by a maneuver of manual compression of the abdomen.

Results: The variable with the strongest effect on auto-PEEP was flow limitation, which was associated with an increase of 2.4 cm H2O in auto-PEEP values. Moreover, auto-PEEP values were directly related to resistance of the respiratory system and body mass index and inversely related to expiratory time/time constant. Variables that were associated with the breathing pattern (tidal volume, frequency minute ventilation, and expiratory time) did not show any relationship with auto-PEEP values. The risk of auto-PEEP ≥5 cm H2O was increased by flow limitation (adjusted odds ratio 17; 95% CI: 6-56.2), expiratory time/time constant ratio <1.85 (12.6; 4.7-39.6), respiratory system resistance >15 cm H2O/L s (3; 1.3-6.9), age >65 y (2.8; 1.2-6.5), and body mass index >26 kg/m(2) (2.6; 1.1-6.1).

Conclusions: Flow limitation, expiratory time/time constant, resistance of the respiratory system, and obesity are the most important variables that affect auto-PEEP values. Frequency expiratory time, tidal volume, and minute ventilation were not independently associated with auto-PEEP. Therapeutic strategies aimed at reducing auto-PEEP and its adverse effects should be primarily oriented to the variables that mainly affect auto-PEEP values.

Citing Articles

[Measurement of intrinsic positive end-expiratory pressure and clinical outcomes of infants with severe bronchopulmonary dysplasia].

Qin X, Zhao X, Zhang H Zhongguo Dang Dai Er Ke Za Zhi. 2024; 26(10):1034-1039.

PMID: 39467671 PMC: 11527413. DOI: 10.7499/j.issn.1008-8830.2404133.


Myths and Misconceptions of Airway Pressure Release Ventilation: Getting Past the Noise and on to the Signal.

Andrews P, Shiber J, Madden M, Nieman G, Camporota L, Habashi N Front Physiol. 2022; 13:928562.

PMID: 35957991 PMC: 9358044. DOI: 10.3389/fphys.2022.928562.


Invasive mechanical ventilation in the emergency department.

Bayram B, Sanci E Turk J Emerg Med. 2019; 19(2):43-52.

PMID: 31065603 PMC: 6495062. DOI: 10.1016/j.tjem.2019.03.001.