» Articles » PMID: 35898020

Quantitative Analysis Using Consecutive Time Window for Unobtrusive Atrial Fibrillation Detection Based on Ballistocardiogram Signal

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2022 Jul 28
PMID 35898020
Authors
Affiliations
Soon will be listed here.
Abstract

Atrial fibrillation (AF) is the most common clinically significant arrhythmia; therefore, AF detection is crucial. Here, we propose a novel feature extraction method to improve AF detection performance using a ballistocardiogram (BCG), which is a weak vibration signal on the body surface transmitted by the cardiogenic force. In this paper, continuous time windows (CTWs) are added to each BCG segment and recurrence quantification analysis (RQA) features are extracted from each time window. Then, the number of CTWs is discussed and the combined features from multiple time windows are ranked, which finally constitute the CTW-RQA features. As validation, the CTW-RQA features are extracted from 4000 BCG segments of 59 subjects, which are compared with classical time and time-frequency features and up-to-date energy features. The accuracy of the proposed feature is superior, and three types of features are fused to obtain the highest accuracy of 95.63%. To evaluate the importance of the proposed feature, the fusion features are ranked using a chi-square test. CTW-RQA features account for 60% of the first 10 fusion features and 65% of the first 17 fusion features. It follows that the proposed CTW-RQA features effectively supplement the existing BCG features for AF detection.

Citing Articles

Heart rate estimation from ballistocardiogram signals processing via low-cost telemedicine architectures: a comparative performance evaluation.

Tramontano A, Tamburis O, Cioce S, Venticinque S, Magliulo M Front Digit Health. 2023; 5:1222898.

PMID: 37583833 PMC: 10424792. DOI: 10.3389/fdgth.2023.1222898.

References
1.
Kirchhof P . The future of atrial fibrillation management: integrated care and stratified therapy. Lancet. 2017; 390(10105):1873-1887. DOI: 10.1016/S0140-6736(17)31072-3. View

2.
Xiong Z, Stiles M, Gillis A, Zhao J . Enhancing the detection of atrial fibrillation from wearable sensors with neural style transfer and convolutional recurrent networks. Comput Biol Med. 2022; 146:105551. DOI: 10.1016/j.compbiomed.2022.105551. View

3.
Jiang F, Zhou Y, Ling T, Zhang Y, Zhu Z . Recent Research for Unobtrusive Atrial Fibrillation Detection Methods Based on Cardiac Dynamics Signals: A Survey. Sensors (Basel). 2021; 21(11). PMC: 8199222. DOI: 10.3390/s21113814. View

4.
Jung S, Lee H, Kang I, Shin S, Chang Y, Shin D . Clinical Implications of Atrial Fibrillation Detection Using Wearable Devices in Patients With Cryptogenic Stroke (CANDLE-AF) Trial: Design and Rationale. Front Cardiovasc Med. 2022; 9:837958. PMC: 9013795. DOI: 10.3389/fcvm.2022.837958. View

5.
Go A, Hylek E, Phillips K, Chang Y, Henault L, Selby J . Prevalence of diagnosed atrial fibrillation in adults: national implications for rhythm management and stroke prevention: the AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study. JAMA. 2001; 285(18):2370-5. DOI: 10.1001/jama.285.18.2370. View