» Articles » PMID: 35848227

Energy Layer Optimization Via Energy Matrix Regularization for Proton Spot-scanning Arc Therapy

Overview
Journal Med Phys
Specialty Biophysics
Date 2022 Jul 18
PMID 35848227
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Spot-scanning arc therapy (SPArc) is an emerging proton modality that can potentially offer a combination of advantages in plan quality and delivery efficiency, compared with traditional IMPT of a few beam angles. Unlike IMPT, frequent low-to-high energy layer switching (so called switch-up (SU)) can degrade delivery efficiency for SPArc. However, it is a tradeoff between the minimization of SU times and the optimization of plan quality. This work will consider the energy layer optimization (ELO) problem for SPArc and develop a new ELO method via energy matrix (EM) regularization to improve plan quality and delivery efficiency.

Methods: The major innovation of EM method for ELO is to design an EM that encourages desirable energy-layer map with minimal SU during SPArc, and then incorporate this EM into the SPArc treatment planning to simultaneously minimize the number of SU and optimize plan quality. The EM method is solved by the fast iterative shrinkage-thresholding algorithm and validated in comparison with a state-of-the-art method, so-called energy sequencing (ES).

Results: EM is validated and compared with ES using representative clinical cases. In terms of delivery efficiency, EM had fewer SU than ES with an average of 35% reduction of SU. In terms of plan quality, compared with ES, EM had smaller optimization objective values and better target dose conformality, and generally lower dose to organs-at-risk and lower integral dose to body. In terms of computational efficiency, EM was substantially more efficient than ES by at least 10-fold.

Conclusion: We have developed a new ELO method for SPArc using EM regularization and shown that this new method EM can improve both delivery efficiency and plan quality, with substantially reduced computational time, compared with ES.

Citing Articles

Emulating the Delivery of Sawtooth Proton Arc Therapy Plans on a Cyclotron-Based Proton Beam Therapy System.

Burford-Eyre S, Aitkenhead A, Aylward J, Henthorn N, Ingram S, Mackay R Cancers (Basel). 2024; 16(19).

PMID: 39409935 PMC: 11475827. DOI: 10.3390/cancers16193315.


TEAM: Triangular-mEsh Adaptive and Multiscale proton spot generation method.

Wang C, Lin B, Lin Y, Shontz S, Huang W, Chen R Med Phys. 2024; 51(10):7067-7079.

PMID: 39140647 PMC: 11479855. DOI: 10.1002/mp.17352.


Simultaneous dose and dose rate optimization via dose modifying factor modeling for FLASH effective dose.

Ma J, Lin Y, Tang M, Zhu Y, Gan G, Rotondo R Med Phys. 2024; 51(8):5190-5203.

PMID: 38873848 PMC: 11783338. DOI: 10.1002/mp.17251.


Biological optimization for hybrid proton-photon radiotherapy.

Li W, Lin Y, Li H, Shen X, Chen R, Gao H Phys Med Biol. 2024; 69(11).

PMID: 38759678 PMC: 11260294. DOI: 10.1088/1361-6560/ad4d51.


FLASH instead of proton arc therapy is a more promising advancement for the next generation proton radiotherapy.

Kang M, Ding X, Rong Y J Appl Clin Med Phys. 2023; 24(8):e14091.

PMID: 37431574 PMC: 10402688. DOI: 10.1002/acm2.14091.


References
1.
Lin Y, Kooy H, Craft D, Depauw N, Flanz J, Clasie B . A Greedy reassignment algorithm for the PBS minimum monitor unit constraint. Phys Med Biol. 2016; 61(12):4665-78. DOI: 10.1088/0031-9155/61/12/4665. View

2.
Cai J, Chen R, Fan J, Gao H . Minimum-monitor-unit optimization via a stochastic coordinate descent method. Phys Med Biol. 2021; 67(1). PMC: 9295687. DOI: 10.1088/1361-6560/ac4212. View

3.
Gu W, Ruan D, Lyu Q, Zou W, Dong L, Sheng K . A novel energy layer optimization framework for spot-scanning proton arc therapy. Med Phys. 2020; 47(5):2072-2084. PMC: 7234928. DOI: 10.1002/mp.14083. View

4.
Sandison G, Papiez E, Bloch C, Morphis J . Phantom assessment of lung dose from proton arc therapy. Int J Radiat Oncol Biol Phys. 1997; 38(4):891-7. DOI: 10.1016/s0360-3016(97)00059-x. View

5.
Lin Y, Clasie B, Liu T, McDonald M, Langen K, Gao H . Minimum-MU and sparse-energy-layer (MMSEL) constrained inverse optimization method for efficiently deliverable PBS plans. Phys Med Biol. 2019; 64(20):205001. DOI: 10.1088/1361-6560/ab4529. View