» Articles » PMID: 31082813

Minimum MU Optimization (MMO): an Inverse Optimization Approach for the PBS Minimum MU Constraint

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2019 May 15
PMID 31082813
Citations 15
Authors
Affiliations
Soon will be listed here.
Abstract

The deliverability of proton pencil beam scanning (PBS) treatment plans is subject to the minimum monitor unit (MU) constraint. This work introduces an inverse optimization approach to enforce the minimum MU constraint on planned spots, for accurate delivery of the planned dose. We formulate the minimum MU problem as an inverse optimization problem that accounts for the minimum MU constraint, i.e. minimum MU optimization (MMO). The MMO minimizes the difference between planned dose and deliverable dose while simultaneously enforcing the minimum MU constraint. Owing to the minimum MU constraint, MMO is nonconvex. Iterative convex relaxations are applied so that a sequence of convex subproblems of MMO need to be solved. The solution algorithm to the convex subproblem is developed based on alternating direction method of multipliers (ADMM). The MMO is validated in comparison with a greedy reassignment (GR) algorithm, and the γ-index results suggest MMO can provide more accurate deliverable plans than GR. A simple-to-implement ADMM based MMO is developed to deal with the minimum MU constraint for high-quality deliverable PBS treatment plans.

Citing Articles

Direct minimization of normal-tissue toxicity via an NTCP-based IMPT planning method.

Wang W, Li W, Li J, Lin Y, Liu X, Qin B Med Phys. 2024; 52(3):1399-1407.

PMID: 39625225 PMC: 11882377. DOI: 10.1002/mp.17559.


TEAM: Triangular-mEsh Adaptive and Multiscale proton spot generation method.

Wang C, Lin B, Lin Y, Shontz S, Huang W, Chen R Med Phys. 2024; 51(10):7067-7079.

PMID: 39140647 PMC: 11479855. DOI: 10.1002/mp.17352.


Optimal minimum MU for intensity-modulated proton therapy with pencil-beam scanning proton beams.

Yi B, Mossahebi S, Jatczak J, Mundis M, Houser T, Alicia D J Appl Clin Med Phys. 2024; 25(9):e14435.

PMID: 38922754 PMC: 11492354. DOI: 10.1002/acm2.14435.


Simultaneous dose and dose rate optimization via dose modifying factor modeling for FLASH effective dose.

Ma J, Lin Y, Tang M, Zhu Y, Gan G, Rotondo R Med Phys. 2024; 51(8):5190-5203.

PMID: 38873848 PMC: 11783338. DOI: 10.1002/mp.17251.


Biological optimization for hybrid proton-photon radiotherapy.

Li W, Lin Y, Li H, Shen X, Chen R, Gao H Phys Med Biol. 2024; 69(11).

PMID: 38759678 PMC: 11260294. DOI: 10.1088/1361-6560/ad4d51.