» Articles » PMID: 35742458

The Assessment of Indoor Formaldehyde and Bioaerosol Removal by Using Negative Discharge Electrostatic Air Cleaners

Overview
Publisher MDPI
Date 2022 Jun 24
PMID 35742458
Authors
Affiliations
Soon will be listed here.
Abstract

This study investigated the single-pass performance of a negative corona electrostatic precipitators (ESP) in removing suspended particulates (PM and PM), formaldehyde (HCHO), and bioaerosols (bacteria and fungi) and measured the ozone (O) concentration generated by ESP. The experimental results revealed that if the operational conditions for the ESP were set to high voltage (-10.5 kV) and low air flow rate (2.4 m/min), ESP had optimal air pollutant removal efficiency. In the laboratory system, its PM and PM removal rates both reached 99% at optimal conditions, and its HCHO removal rate was 55%. In field tests, its PM, PM, HCHO, bacteria, and fungi removal rates reached 89%, 90%, 46%, 69%, and 85% respectively. The ESP in the laboratory system (-10.5 kV and 2.4 m/min) generated 7.374 ppm of O under optimal conditions. Under the same operational conditions, O generated by ESP in the food waste storage room and the meeting room were 1.347 ppm and 1.749 ppm, respectively. The removal of HCHO and bioaerosols was primarily attributed to their destruction in the corona, as well as ozone oxidation, and collection on the dust collection plate.

References
1.
Nunez C, Ramsey G, Ponder W, Abbott J, Hamel L, Kariher P . Corona destruction: an innovative control technology for VOCs and air toxics. Air Waste. 1993; 43(2):242-7. DOI: 10.1080/1073161x.1993.10467131. View

2.
Chang M, Lee C . Destruction of formaldehyde with dielectric barrier discharge plasmas. Environ Sci Technol. 2011; 29(1):181-6. DOI: 10.1021/es00001a023. View

3.
Lee S, Willeke K, Mainelis G, Adhikari A, Wang H, Reponen T . Assessment of electrical charge on airborne microorganisms by a new bioaerosol sampling method. J Occup Environ Hyg. 2004; 1(3):127-38. DOI: 10.1080/15459620490424357. View

4.
Niazi S, Hassanvand M, Mahvi A, Nabizadeh R, Alimohammadi M, Nabavi S . Assessment of bioaerosol contamination (bacteria and fungi) in the largest urban wastewater treatment plant in the Middle East. Environ Sci Pollut Res Int. 2015; 22(20):16014-21. DOI: 10.1007/s11356-015-4793-z. View

5.
Dyas A, Boughton B, Das B . Ozone killing action against bacterial and fungal species; microbiological testing of a domestic ozone generator. J Clin Pathol. 1983; 36(10):1102-4. PMC: 498483. DOI: 10.1136/jcp.36.10.1102. View