The new ionization technique termed vibrating sharp-edge spray ionization (cVSSI) has been coupled with corona discharge to investigate atmospheric pressure chemical ionization (APCI) capabilities. The optimized source was evaluated for its ability to enhance ion signal intensity, overcome matrix effects, and limit ion suppression. The results have been compared with state-of-the-art ESI source performance as well as a new APCI-like source. In methanol, the ion signal intensity increased 10-fold and >10-fold for cocaine and the suppressed analytes, respectively. The ability to overcome ion suppression was improved from 2-fold to 16-fold for theophylline and vitamin D2, respectively. For aqueous samples, ion signal levels increased by two orders of magnitude for all analytes. In both solvent systems, the signal-to-noise ratios also increased for all suppressed analytes. One example of the characterization of low-ionizing (by ESI or cVSSI alone) species in the presence of high-ionizing species by direct analysis from a cotton swab is presented. The work is discussed with respect to the advantages of cVSSI-APCI for direct, in situ, and field analyses.

Citing Articles

Applications of ambient ionization mass spectrometry in 2022: An annual review.

Rankin-Turner S, Sears P, Heaney L Anal Sci Adv. 2024; 4(5-6):133-153.

PMID: 38716065 PMC: 10989672. DOI: 10.1002/ansa.202300004.


Solvent-Assisted Laser Desorption Flexible Microtube Plasma Mass Spectrometry for Direct Analysis of Dried Samples on Paper.

Bouza M, Ahlmann N, Garcia-Reyes J, Franzke J Anal Chem. 2023; 95(50):18370-18378.

PMID: 37902451 PMC: 10733904. DOI: 10.1021/acs.analchem.3c03009.


Acoustic Atomization-Induced Pumping Based on a Vibrating Sharp-Tip Capillary.

Mendis B, He Z, Li X, Wang J, Li C, Li P Micromachines (Basel). 2023; 14(6).

PMID: 37374797 PMC: 10301781. DOI: 10.3390/mi14061212.


Portable mass spectrometry system: instrumentation, applications, and path to 'omics analysis.

Wang J, Pursell M, DeVor A, Awoyemi O, Valentine S, Li P Proteomics. 2022; 22(23-24):e2200112.

PMID: 36349734 PMC: 10278091. DOI: 10.1002/pmic.202200112.

References
1.
Kislinger T, Gramolini A, MacLennan D, Emili A . Multidimensional protein identification technology (MudPIT): technical overview of a profiling method optimized for the comprehensive proteomic investigation of normal and diseased heart tissue. J Am Soc Mass Spectrom. 2005; 16(8):1207-20. DOI: 10.1016/j.jasms.2005.02.015. View

2.
Goto-Inoue N, Hayasaka T, Zaima N, Setou M . Imaging mass spectrometry for lipidomics. Biochim Biophys Acta. 2011; 1811(11):961-9. DOI: 10.1016/j.bbalip.2011.03.004. View

3.
Kulyk D, Swiner D, Sahraeian T, Badu-Tawiah A . Direct Mass Spectrometry Analysis of Complex Mixtures by Nanoelectrospray with Simultaneous Atmospheric Pressure Chemical Ionization and Electrophoretic Separation Capabilities. Anal Chem. 2019; 91(18):11562-11568. PMC: 6822699. DOI: 10.1021/acs.analchem.9b01456. View

4.
Song L, You Y, Perdomo N, Evans-Nguyen T . Inexpensive Ultrasonic Nebulization Coupled with Direct Current Corona Discharge Ionization Mass Spectrometry for Liquid Samples and Its Fundamental Investigations. Anal Chem. 2020; 92(16):11072-11079. DOI: 10.1021/acs.analchem.0c00524. View

5.
Niessen W, Manini P, Andreoli R . Matrix effects in quantitative pesticide analysis using liquid chromatography-mass spectrometry. Mass Spectrom Rev. 2006; 25(6):881-99. DOI: 10.1002/mas.20097. View