Insulin Degludec Versus Insulin Glargine on Glycemic Variability in Diabetic Patients: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

Overview
Specialty Endocrinology
Date 2022 Jun 20
PMID 35721710
Authors
Affiliations
Soon will be listed here.
Abstract

Background/aims: Currently, glycemic variability has more deleterious effects than sustained hyperglycemia and is closely associated with acute and chronic complications of diabetes. Reducing glycemic excursion is becoming another vital goal of glycemic control in clinical practice. This study aimed to determine whether insulin degludec (IDeg) or insulin glargine (IGla) was more beneficial for reducing glycemic fluctuations.

Materials And Methods: This research was constructed according to the PRISMA guidelines. We searched eight databases and ClinicalTrials.gov from their inception to 30 November 2021. All randomized controlled trials comparing the efficacy of glucose variability between IDeg and IGla in diabetic patients were included.

Results: Fourteen trials with 8,683 participants were included. In patients with T1DM, IDeg was associated with a lower mean (MD: -16.25, 95% CI -29.02 to -3.07, P = 0.01) and standard deviation (P = 0.03) compared to IGla in fasting blood glucose (FBG); in people with T2DM, IDeg was related to a lower mean of FBG versus insulin glargine 100 U/ml (IGla100) (P <0.001) and had a more extended time in the range (TIR) than IGla100 (SMD: 0.15, 95% CI 0.02 to 0.27, P = 0.02) but not longer than insulin glargine 300 U/ml (IGla300). Moreover, IDeg had a lower coefficient of variation of FBG than IGla (P = 0.0254). For other indicators of glycemic variability, namely, standard deviation of blood glucose for 24 h, the mean of 24-h blood glucose, mean amplitude of glycemic excursion, the coefficient of variation for 24 h, the mean of daily differences, area under the glucose curve, and M-value, no significant differences were identified between IDeg and IGla, regardless of T1DM or T2DM.

Conclusions: Based on the current studies, there was comparable efficacy between IDeg and IGla from multiple aspects of glycemic variability, regardless of T1DM or T2DM. However, IDeg may be superior to IGla in reducing FBG variability in T1DM and T2DM. Nonetheless, due to the limitations of the original studies, it is still unclear whether IDeg is superior to both IGla100 and IGla300. In T2DM, IDeg had more extended TIR than IGla100 but not longer than IGla300. Additionally, more well-designed randomized controlled trials comparing IDeg with IGla300 for different indicators of glycemic variability are still warranted.

Systematic Review Registration: PROSPERO, CRD42021283203.

Citing Articles

Initiation of Insulin Degludec in Chinese Hospitalized Patients with Type 2 Diabetes - A Single Center's Experience.

Qiang W, Li M, Song S, Dong R, Zhang T, Kou X Diabetes Metab Syndr Obes. 2024; 17:3535-3546.

PMID: 39328263 PMC: 11425662. DOI: 10.2147/DMSO.S468070.


Glycemic Variability in Pancreatogenic Diabetes Mellitus: characteristics, Risks, Potential Mechanisms, and Treatment Possibilities.

Sun Y, Lu B, Hu Y, Lv Y, Zhong S Int J Gen Med. 2024; 17:4297-4309.

PMID: 39324147 PMC: 11423834. DOI: 10.2147/IJGM.S477497.


Efficacy and safety of insulin glargine 300 units/mL vs insulin degludec in patients with type 1 and type 2 diabetes: a systematic review and meta-analysis.

Alhmoud E, Saad M, Omar N Front Endocrinol (Lausanne). 2024; 14:1285147.

PMID: 38313835 PMC: 10836592. DOI: 10.3389/fendo.2023.1285147.


What is Glycaemic Variability and which Pharmacological Treatment Options are Effective? A Narrative Review.

Canas J, Gutierrez M, Ossa A touchREV Endocrinol. 2023; 19(2):16-21.

PMID: 38046184 PMC: 10688563. DOI: 10.17925/EE.2023.19.2.4.


Impact of protocolized fluid management on electrolyte stability in patients undergoing continuous renal replacement therapy.

Baeg S, Jeon J, Kang D, Na S, Cho J, Kim K Front Med (Lausanne). 2022; 9:915072.

PMID: 36117982 PMC: 9471083. DOI: 10.3389/fmed.2022.915072.

References
1.
Onda Y, Nishimura R, Ando K, Takahashi H, Tsujino D, Utsunomiya K . Comparison of glycemic variability in Japanese patients with type 1 diabetes receiving insulin degludec versus insulin glargine using continuous glucose monitoring: A randomized, cross-over, pilot study. Diabetes Res Clin Pract. 2016; 120:149-55. DOI: 10.1016/j.diabres.2016.07.019. View

2.
Meneghini L, Atkin S, Gough S, Raz I, Blonde L, Shestakova M . The efficacy and safety of insulin degludec given in variable once-daily dosing intervals compared with insulin glargine and insulin degludec dosed at the same time daily: a 26-week, randomized, open-label, parallel-group, treat-to-target trial in.... Diabetes Care. 2013; 36(4):858-64. PMC: 3609505. DOI: 10.2337/dc12-1668. View

3.
Takahashi H, Iwahashi N, Kirigaya J, Kataoka S, Minamimoto Y, Gohbara M . Glycemic variability determined with a continuous glucose monitoring system can predict prognosis after acute coronary syndrome. Cardiovasc Diabetol. 2018; 17(1):116. PMC: 6098663. DOI: 10.1186/s12933-018-0761-5. View

4.
Wan X, Wang W, Liu J, Tong T . Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile range. BMC Med Res Methodol. 2014; 14:135. PMC: 4383202. DOI: 10.1186/1471-2288-14-135. View

5.
Hirakawa Y, Arima H, Zoungas S, Ninomiya T, Cooper M, Hamet P . Impact of visit-to-visit glycemic variability on the risks of macrovascular and microvascular events and all-cause mortality in type 2 diabetes: the ADVANCE trial. Diabetes Care. 2014; 37(8):2359-65. DOI: 10.2337/dc14-0199. View