Ultrasound in Labor: Clinical Practice Guideline and Recommendation by the WAPM-World Association of Perinatal Medicine and the PMF-Perinatal Medicine Foundation

Overview
Journal J Perinat Med
Date 2022 May 26
PMID 35618672
Authors
Affiliations
Soon will be listed here.
Abstract

This recommendation document follows the mission of the World Association of Perinatal Medicine in collaboration with the Perinatal Medicine Foundation. We aim to bring together groups and individuals throughout the world for standardization to implement the ultrasound evaluation in labor ward and improve the clinical management of labor. Ultrasound in labor can be performed using a transabdominal or a transperineal approach depending upon which parameters are being assessed. During transabdominal imaging, fetal anatomy, presentation, liquor volume, and placental localization can be determined. The transperineal images depict images of the fetal head in which calculations to determine a proposed fetal head station can be made.

Citing Articles

Effect of an online teaching module on midwives' knowledge, attitude and practice regarding intrapartum ultrasound: A quasi-experimental approach.

Packet B, Adela S, Jute R Eur J Midwifery. 2024; 10.

PMID: 39664889 PMC: 11633044. DOI: 10.18332/ejm/195498.


Intrapartum Ultrasound Guidance to Make Safer Any Obstetric Intervention: Fetal Head Rotation, Assisted Vaginal Birth, Breech Delivery of the Second Twin.

DallAsta A, Melito C, Ghi T Clin Obstet Gynecol. 2024; 67(4):730-738.

PMID: 39431493 PMC: 11495479. DOI: 10.1097/GRF.0000000000000891.


Ensemble learning for fetal ultrasound and maternal-fetal data to predict mode of delivery after labor induction.

Ferreira I, Simoes J, Pereira B, Correia J, Areia A Sci Rep. 2024; 14(1):15275.

PMID: 38961231 PMC: 11222528. DOI: 10.1038/s41598-024-65394-6.


Prediction of Failure to Progress after Labor Induction: A Multivariable Model Using Pelvic Ultrasound and Clinical Data.

Novillo-Del Alamo B, Martinez-Varea A, Satorres-Perez E, Nieto-Tous M, Modrego-Pardo F, Padilla-Prieto C J Pers Med. 2024; 14(5).

PMID: 38793084 PMC: 11122556. DOI: 10.3390/jpm14050502.


Artificial Intelligence, Intrapartum Ultrasound and Dystocic Delivery: AIDA (Artificial Intelligence Dystocia Algorithm), a Promising Helping Decision Support System.

Malvasi A, Malgieri L, Cicinelli E, Vimercati A, Damato A, Dellino M J Imaging. 2024; 10(5).

PMID: 38786561 PMC: 11122467. DOI: 10.3390/jimaging10050107.