Effects of Total Knee Replacement Design on Femoral-tibial Contact Conditions

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 1986 Jan 1
PMID 3559575
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Ten fresh knee specimens with prosthetic components inserted were tested in a loading rig. Compressive and shear force were applied to the femur with the tibia held fixed. The location of the femoral-tibial contact points was measured. The contact reaction forces, the shear forces, and the rocking moments transmitted to the tibial component were calculated. The variations in the test conditions were: high and low compressive force, flexion angles of 0 degree, 45 degrees, and 90 degrees, three curvatures of tibial plastic inserts, and the posterior cruciate retained or resected. When the posterior cruciate was retained, the contact points were close to the center of the component; for cruciate resection, the contacts were close to the anterior of the component. The shear forces and rocking moments were higher for cruciate resection, but the contact reaction forces were lower. There is a wide variety of knee prosthesis designs, but the amount of inherent stability between the femoral and tibial surfaces, and whether the posterior cruciate ligament is retained or sacrificed, are two of the most important design variables. This study shows that cruciate resection increases the shear forces and the rocking moments to the tibial components and that additional fixation means may be necessary to compensate. On the other hand, cruciate retention with low conformity gives higher contact forces, which may lead to more wear in the long term. Cruciate sacrificing designs with intercondylar guiding surfaces are a separate category of design and were not considered in this study.

Citing Articles

Nontraumatic Tibial Polyethylene Insert Cone Fracture in Rotating-Platform Total Knee Arthroplasty.

Keogh C, Keohane D, Harty J, Mulcahy D Arthroplast Today. 2021; 8:283-288.e1.

PMID: 34095405 PMC: 8167323. DOI: 10.1016/j.artd.2021.02.013.


Patellofemoral resurfacing and patellar denervation in primary total knee arthroplasty.

Arirachakaran A, Sangkaew C, Kongtharvonskul J Knee Surg Sports Traumatol Arthrosc. 2014; 23(6):1770-81.

PMID: 25218579 DOI: 10.1007/s00167-014-3311-z.


Retain or sacrifice the posterior cruciate ligament in total knee arthroplasty? A histopathological study of the cruciate ligament in osteoarthritic and rheumatoid disease.

Nelissen R, Hogendoorn P J Clin Pathol. 2001; 54(5):381-4.

PMID: 11328838 PMC: 1731430. DOI: 10.1136/jcp.54.5.381.


Posterior cruciate ligament function following total knee arthroplasty: the effect of joint line elevation.

Emodi G, Callaghan J, Pedersen D, Brown T Iowa Orthop J. 2000; 19:82-92.

PMID: 10847521 PMC: 1888617.


Kinematics of successful knee prostheses during weight-bearing: three-dimensional movements and positions of screw axes in the Tricon-M and Miller-Galante designs.

Karrholm J, Jonsson H, Nilsson K, Soderqvist I Knee Surg Sports Traumatol Arthrosc. 1994; 2(1):50-9.

PMID: 7584178 DOI: 10.1007/BF01552655.