» Articles » PMID: 35534575

An Integrated Wearable Microneedle Array for the Continuous Monitoring of Multiple Biomarkers in Interstitial Fluid

Abstract

Implementations of wearable microneedle-based arrays of sensors for the monitoring of multiple biomarkers in interstitial fluid have lacked system integration and evidence of robust analytical performance. Here we report the development and testing of a fully integrated wearable array of microneedles for the wireless and continuous real-time sensing of two metabolites (lactate and glucose, or alcohol and glucose) in the interstitial fluid of volunteers performing common daily activities. The device works with a custom smartphone app for data capture and visualization, comprises reusable electronics and a disposable microneedle array, and is optimized for system integration, cost-effective fabrication via advanced micromachining, easier assembly, biocompatibility, pain-free skin penetration and enhanced sensitivity. Single-analyte and dual-analyte measurements correlated well with the corresponding gold-standard measurements in blood or breath. Further validation of the technology in large populations with concurrent validation of sensor readouts through centralized laboratory tests should determine the robustness and utility of real-time simultaneous monitoring of several biomarkers in interstitial fluid.

Citing Articles

Mind the Gap: Wearable Lactate and Glucose Monitors for Hospitalized Patients.

Guzzi J, Falter F, Kumar A, Perrino Jr A Cureus. 2025; 17(2):e78536.

PMID: 40062120 PMC: 11886925. DOI: 10.7759/cureus.78536.


A Comprehensive Review of Advanced Lactate Biosensor Materials, Methods, and Applications in Modern Healthcare.

Ding Y, Yang L, Wen J, Ma Y, Dai G, Mo F Sensors (Basel). 2025; 25(4).

PMID: 40006275 PMC: 11858931. DOI: 10.3390/s25041045.


Self-calibrating multiplexed microneedle electrode array for continuous mapping of subcutaneous multi-analytes in diabetes.

Li X, Zheng S, He M, Huang X, Yang C, Mo J Innovation (Camb). 2025; 6(2):100781.

PMID: 39991476 PMC: 11846035. DOI: 10.1016/j.xinn.2024.100781.


Implantable photoelectrochemical-therapeutic methotrexate monitoring system with dual-atomic docking strategy.

Xu X, Xu D, Zhou X, Huang J, Gu S, Zhang Z Nat Commun. 2025; 16(1):1747.

PMID: 39966460 PMC: 11836052. DOI: 10.1038/s41467-025-57084-2.


Nanozyme-based wearable biosensors for application in healthcare.

Zhang Y, Yang Y, Yin Z, Huang L, Wang J iScience. 2025; 28(2):111763.

PMID: 39906563 PMC: 11791255. DOI: 10.1016/j.isci.2025.111763.


References
1.
Kim J, Campbell A, de Avila B, Wang J . Wearable biosensors for healthcare monitoring. Nat Biotechnol. 2019; 37(4):389-406. PMC: 8183422. DOI: 10.1038/s41587-019-0045-y. View

2.
Dunn J, Runge R, Snyder M . Wearables and the medical revolution. Per Med. 2018; 15(5):429-448. DOI: 10.2217/pme-2018-0044. View

3.
Gao W, Emaminejad S, Nyein H, Challa S, Chen K, Peck A . Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis. Nature. 2016; 529(7587):509-514. PMC: 4996079. DOI: 10.1038/nature16521. View

4.
Heikenfeld J, Jajack A, Rogers J, Gutruf P, Tian L, Pan T . Wearable sensors: modalities, challenges, and prospects. Lab Chip. 2017; 18(2):217-248. PMC: 5771841. DOI: 10.1039/c7lc00914c. View

5.
Ray T, Choi J, Bandodkar A, Krishnan S, Gutruf P, Tian L . Bio-Integrated Wearable Systems: A Comprehensive Review. Chem Rev. 2019; 119(8):5461-5533. DOI: 10.1021/acs.chemrev.8b00573. View