» Articles » PMID: 35516810

Complex-Amplitude-Modulation Vectorial Excitation Beam for High-Resolution Observation of Deep Regions in Two-Photon Microscopy

Overview
Journal Front Neurosci
Date 2022 May 6
PMID 35516810
Authors
Affiliations
Soon will be listed here.
Abstract

In two-photon microscopy, aberration correction is an essential technique for realizing high resolution in deep regions. A spatial light modulator (SLM) incorporated into an optical system for two-photon microscopy performs pre-compensation on the wavefront of the excitation beam, restoring the resolution close to the diffraction limit even in the deep region of a biological sample. If a spatial resolution smaller than the diffraction limit can be achieved along with aberration correction, the importance of two-photon microscopy for deep region observation will increase further. In this study, we realize higher resolution observations in the deep region by combining two resolution-enhancement methods and an aberration correction method. Therefore, a z-polarizer is added to the aberration-correction optical system, and the SLM modulates the amplitude and phase of the excitation beam; in other words, complex-amplitude modulation is performed. The lateral resolution is found to be approximately 20% higher than the diffraction limit obtained using a circularly polarized beam. Verification was conducted by simulation and experimentation using model samples and biological samples. The proposed method has the potential to be effective for live imaging and photostimulation of the deep region of the sample, although it requires only minor changes to the conventional optical system that performs aberration correction.

References
1.
Ji N, Sato T, Betzig E . Characterization and adaptive optical correction of aberrations during in vivo imaging in the mouse cortex. Proc Natl Acad Sci U S A. 2011; 109(1):22-7. PMC: 3252919. DOI: 10.1073/pnas.1109202108. View

2.
Kawai S, Takagi Y, Kaneko S, Kurosawa T . Effect of three types of mixed anesthetic agents alternate to ketamine in mice. Exp Anim. 2011; 60(5):481-7. DOI: 10.1538/expanim.60.481. View

3.
Nikolenko V, Watson B, Araya R, Woodruff A, Peterka D, Yuste R . SLM Microscopy: Scanless Two-Photon Imaging and Photostimulation with Spatial Light Modulators. Front Neural Circuits. 2009; 2:5. PMC: 2614319. DOI: 10.3389/neuro.04.005.2008. View

4.
Matsumoto N, Inoue T, Matsumoto A, Okazaki S . Correction of depth-induced spherical aberration for deep observation using two-photon excitation fluorescence microscopy with spatial light modulator. Biomed Opt Express. 2015; 6(7):2575-87. PMC: 4505711. DOI: 10.1364/BOE.6.002575. View

5.
Li X, Venugopalan P, Ren H, Hong M, Gu M . Super-resolved pure-transverse focal fields with an enhanced energy density through focus of an azimuthally polarized first-order vortex beam. Opt Lett. 2014; 39(20):5961-4. DOI: 10.1364/OL.39.005961. View