6.
Spence J, Schmidt K, Wu J, Hembree G, Weierstall U, Doak B
. Diffraction and imaging from a beam of laser-aligned proteins: resolution limits. Acta Crystallogr A. 2005; 61(Pt 2):237-45.
DOI: 10.1107/S0108767305002710.
View
7.
Ayyer K, Yefanov O, Oberthur D, Roy-Chowdhury S, Galli L, Mariani V
. Macromolecular diffractive imaging using imperfect crystals. Nature. 2016; 530(7589):202-6.
PMC: 4839592.
DOI: 10.1038/nature16949.
View
8.
Rodriguez J, Xu R, Chen C, Zou Y, Miao J
. Oversampling smoothness: an effective algorithm for phase retrieval of noisy diffraction intensities. J Appl Crystallogr. 2013; 46(Pt 2):312-318.
PMC: 3627409.
DOI: 10.1107/S0021889813002471.
View
9.
KENDREW J, Bodo G, Dintzis H, PARRISH R, WYCKOFF H, Phillips D
. A three-dimensional model of the myoglobin molecule obtained by x-ray analysis. Nature. 1958; 181(4610):662-6.
DOI: 10.1038/181662a0.
View
10.
Nakane T, Hanashima S, Suzuki M, Saiki H, Hayashi T, Kakinouchi K
. Membrane protein structure determination by SAD, SIR, or SIRAS phasing in serial femtosecond crystallography using an iododetergent. Proc Natl Acad Sci U S A. 2016; 113(46):13039-13044.
PMC: 5135358.
DOI: 10.1073/pnas.1602531113.
View
11.
Neutze R, Wouts R, van der Spoel D, Weckert E, Hajdu J
. Potential for biomolecular imaging with femtosecond X-ray pulses. Nature. 2000; 406(6797):752-7.
DOI: 10.1038/35021099.
View
12.
Bisgaard C, Poulsen M, Peronne E, Viftrup S, Stapelfeldt H
. Observation of enhanced field-free molecular alignment by two laser pulses. Phys Rev Lett. 2004; 92(17):173004.
DOI: 10.1103/PhysRevLett.92.173004.
View
13.
Pickering J, Shepperson B, Hubschmann B, Thorning F, Stapelfeldt H
. Alignment and Imaging of the CS_{2} Dimer Inside Helium Nanodroplets. Phys Rev Lett. 2018; 120(11):113202.
DOI: 10.1103/PhysRevLett.120.113202.
View
14.
Leibscher M, Averbukh I, Rabitz H
. Molecular alignment by trains of short laser pulses. Phys Rev Lett. 2003; 90(21):213001.
DOI: 10.1103/PhysRevLett.90.213001.
View
15.
Weierstall U, James D, Wang C, White T, Wang D, Liu W
. Lipidic cubic phase injector facilitates membrane protein serial femtosecond crystallography. Nat Commun. 2014; 5:3309.
PMC: 4061911.
DOI: 10.1038/ncomms4309.
View
16.
Rosca-Pruna F, Vrakking M
. Experimental observation of revival structures in picosecond laser-induced alignment of I2. Phys Rev Lett. 2001; 87(15):153902.
DOI: 10.1103/PhysRevLett.87.153902.
View
17.
LARSEN , Hald , Bjerre , Stapelfeldt , Seideman
. Three dimensional alignment of molecules using elliptically polarized laser fields. Phys Rev Lett. 2000; 85(12):2470-3.
DOI: 10.1103/PhysRevLett.85.2470.
View
18.
Redecke L, Nass K, DePonte D, White T, Rehders D, Barty A
. Natively inhibited Trypanosoma brucei cathepsin B structure determined by using an X-ray laser. Science. 2012; 339(6116):227-230.
PMC: 3786669.
DOI: 10.1126/science.1229663.
View
19.
Minitti M, Budarz J, Kirrander A, Robinson J, Ratner D, Lane T
. Imaging Molecular Motion: Femtosecond X-Ray Scattering of an Electrocyclic Chemical Reaction. Phys Rev Lett. 2015; 114(25):255501.
DOI: 10.1103/PhysRevLett.114.255501.
View
20.
Song C, Jiang H, Mancuso A, Amirbekian B, Peng L, Sun R
. Quantitative imaging of single, unstained viruses with coherent x rays. Phys Rev Lett. 2008; 101(15):158101.
DOI: 10.1103/PhysRevLett.101.158101.
View