A Contact-Sensitive Probe for Biomedical Optics

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2022 Mar 26
PMID 35336531
Authors
Affiliations
Soon will be listed here.
Abstract

Capacitive proximity sensing is widespread in our everyday life, but no sensor for biomedical optics takes advantage of this technology to monitor the probe attachment to the subject's skin. In particular, when using optical monitoring devices, the capability to quantitatively measure the probe contact can significantly improve data quality and ensure the subject's safety. We present a custom novel optical probe based on a flexible printed circuit board which integrates a capacitive contact sensor, 3D-printed optic fiber holders and an accelerometer sensor. The device can be effectively adopted during continuous monitoring optical measurements to detect contact quality, motion artifacts, probe detachment and ensure optimal signal quality.

Citing Articles

How the heterogeneity of the severely injured brain affects hybrid diffuse optical signals: case examples and guidelines.

Tagliabue S, Kacprzak M, Rey-Perez A, Baena J, Riveiro M, Maruccia F Neurophotonics. 2024; 11(4):045005.

PMID: 39430435 PMC: 11487584. DOI: 10.1117/1.NPh.11.4.045005.


Chassis-based fiber-coupled optical probe design for reproducible quantitative diffuse optical spectroscopy measurements.

Matlis G, Zhang Q, Benson E, Weeks M, Andersen K, Jahnavi J PLoS One. 2024; 19(7):e0305254.

PMID: 39052686 PMC: 11271963. DOI: 10.1371/journal.pone.0305254.


Multi-wavelength multi-distance diffuse correlation spectroscopy system for assessment of premature infants' cerebral hemodynamics.

Otic N, Sunwoo J, Huang Y, Martin A, Robinson M, Zimmermann B Biomed Opt Express. 2024; 15(3):1959-1975.

PMID: 38495689 PMC: 10942694. DOI: 10.1364/BOE.505783.

References
1.
Sweeney K, Ayaz H, Ward T, Izzetoglu M, McLoone S, Onaral B . A methodology for validating artifact removal techniques for fNIRS. Annu Int Conf IEEE Eng Med Biol Soc. 2012; 2011:4943-6. DOI: 10.1109/IEMBS.2011.6091225. View

2.
Giovannella M, Contini D, Pagliazzi M, Pifferi A, Spinelli L, Erdmann R . BabyLux device: a diffuse optical system integrating diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy for the neuromonitoring of the premature newborn brain. Neurophotonics. 2019; 6(2):025007. PMC: 6509945. DOI: 10.1117/1.NPh.6.2.025007. View

3.
Wolf M, Ferrari M, Quaresima V . Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications. J Biomed Opt. 2008; 12(6):062104. DOI: 10.1117/1.2804899. View

4.
Frijia E, Billing A, Lloyd-Fox S, Vidal Rosas E, Collins-Jones L, Crespo-Llado M . Functional imaging of the developing brain with wearable high-density diffuse optical tomography: A new benchmark for infant neuroimaging outside the scanner environment. Neuroimage. 2020; 225:117490. DOI: 10.1016/j.neuroimage.2020.117490. View

5.
Wu K, Sunwoo J, Sheriff F, Farzam P, Farzam P, Orihuela-Espina F . Validation of diffuse correlation spectroscopy measures of critical closing pressure against transcranial Doppler ultrasound in stroke patients. J Biomed Opt. 2021; 26(3). PMC: 7998065. DOI: 10.1117/1.JBO.26.3.036008. View