» Articles » PMID: 35322152

Lung Tissue Biomechanics Imaged with Synchrotron Phase Contrast Microtomography in Live Rats

Overview
Journal Sci Rep
Specialty Science
Date 2022 Mar 24
PMID 35322152
Authors
Affiliations
Soon will be listed here.
Abstract

The magnitude and distribution of strain imposed on the peripheral airspaces by mechanical ventilation at the microscopic level and the consequent deformations are unknown despite their importance for understanding the mechanisms occurring at the onset of ventilator-induced lung injury. Here a 4-Dimensional (3D + time) image acquisition and processing technique is developed to assess pulmonary acinar biomechanics at microscopic resolution. Synchrotron radiation phase contrast CT with an isotropic voxel size of 6 µm is applied in live anesthetized rats under controlled mechanical ventilation. Video animations of regional acinar and vascular strain are acquired in vivo. Maps of strain distribution due to positive-pressure breaths and cardiovascular activity in lung acini and blood vessels are derived based on CT images. Regional strain within the lung peripheral airspaces takes average values of 0.09 ± 0.02. Fitting the expression S = kV, to the changes in peripheral airspace area (S) and volume (V) during a positive pressure breath yields an exponent n = 0.82 ± 0.03, suggesting predominant alveolar expansion rather than ductal expansion or alveolar recruitment. We conclude that this methodology can be used to assess acinar conformational changes during positive pressure breaths in intact peripheral lung airspaces.

Citing Articles

Multiscale Three-Dimensional Evaluation and Analysis of Murine Lung Vasculature From Macro- to Micro-Structural Level.

Tielemans B, Marain N, Kerstens A, Peredo N, Coll-Llado M, Gritti N Pulm Circ. 2025; 15(1):e70038.

PMID: 39845890 PMC: 11751252. DOI: 10.1002/pul2.70038.


Mapping the strain-stiffening behavior of the lung and lung cancer at microscale resolution using the crystal ribcage.

LeBourdais R, Grifno G, Banerji R, Regan K, Suki B, Nia H Front Netw Physiol. 2024; 4:1396593.

PMID: 39050550 PMC: 11266057. DOI: 10.3389/fnetp.2024.1396593.


Alveolar Microdynamics during Tidal Ventilation in Live Animals Imaged by SPring-8 Synchrotron.

Kim M, Yu S, Yang U, Nukiwa R, Cho H, Kwon N Adv Sci (Weinh). 2024; 11(33):e2306256.

PMID: 38959397 PMC: 11434049. DOI: 10.1002/advs.202306256.


3D imaging of SARS-CoV-2 infected hamster lungs by X-ray phase contrast tomography enables drug testing.

Reichmann J, Sarrazin C, Schmale S, Blaurock C, Balkema-Buschmann A, Schmitzer B Sci Rep. 2024; 14(1):12348.

PMID: 38811688 PMC: 11137149. DOI: 10.1038/s41598-024-61746-4.


The fix is not yet in: recommendation for fixation of lungs within physiological/pathophysiological volume range in preclinical pulmonary structure-function studies.

Perlman C, Knudsen L, Smith B Am J Physiol Lung Cell Mol Physiol. 2024; 327(2):L218-L231.

PMID: 38712433 PMC: 11444500. DOI: 10.1152/ajplung.00341.2023.


References
1.
Slutsky A, Ranieri V . Ventilator-induced lung injury. N Engl J Med. 2013; 369(22):2126-36. DOI: 10.1056/NEJMra1208707. View

2.
Dubsky S, Hooper S, Siu K, Fouras A . Synchrotron-based dynamic computed tomography of tissue motion for regional lung function measurement. J R Soc Interface. 2012; 9(74):2213-24. PMC: 3405755. DOI: 10.1098/rsif.2012.0116. View

3.
Gil J, Bachofen H, Gehr P, Weibel E . Alveolar volume-surface area relation in air- and saline-filled lungs fixed by vascular perfusion. J Appl Physiol Respir Environ Exerc Physiol. 1979; 47(5):990-1001. DOI: 10.1152/jappl.1979.47.5.990. View

4.
Smaldone G, Mitzner W . Viewpoint: unresolved mysteries. J Appl Physiol (1985). 2012; 113(12):1945-7. PMC: 4587588. DOI: 10.1152/japplphysiol.00545.2012. View

5.
Denny E, Schroter R . Relationships between alveolar size and fibre distribution in a mammalian lung alveolar duct model. J Biomech Eng. 1997; 119(3):289-97. DOI: 10.1115/1.2796093. View