» Articles » PMID: 22491972

Synchrotron-based Dynamic Computed Tomography of Tissue Motion for Regional Lung Function Measurement

Overview
Date 2012 Apr 12
PMID 22491972
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

During breathing, lung inflation is a dynamic process involving a balance of mechanical factors, including trans-pulmonary pressure gradients, tissue compliance and airway resistance. Current techniques lack the capacity for dynamic measurement of ventilation in vivo at sufficient spatial and temporal resolution to allow the spatio-temporal patterns of ventilation to be precisely defined. As a result, little is known of the regional dynamics of lung inflation, in either health or disease. Using fast synchrotron-based imaging (up to 60 frames s(-1)), we have combined dynamic computed tomography (CT) with cross-correlation velocimetry to measure regional time constants and expansion within the mammalian lung in vivo. Additionally, our new technique provides estimation of the airflow distribution throughout the bronchial tree during the ventilation cycle. Measurements of lung expansion and airflow in mice and rabbit pups are shown to agree with independent measures. The ability to measure lung function at a regional level will provide invaluable information for studies into normal and pathological lung dynamics, and may provide new pathways for diagnosis of regional lung diseases. Although proof-of-concept data were acquired on a synchrotron, the methodology developed potentially lends itself to clinical CT scanning and therefore offers translational research opportunities.

Citing Articles

Using X-ray velocimetry to measure lung function and assess the efficacy of a pseudomonas aeruginosa bacteriophage therapy for cystic fibrosis.

Harker S, Preissner M, Chang R, Trevascus D, Liu C, Wang Y Sci Rep. 2024; 14(1):29727.

PMID: 39614107 PMC: 11607086. DOI: 10.1038/s41598-024-80326-0.


Assessment of respiratory mechanics and X-ray velocimetry functional imaging in two cystic fibrosis rat models.

Reyne N, Smith R, Cmielewski P, Eikelis N, Lawrence M, Louise J Sci Rep. 2024; 14(1):21646.

PMID: 39284856 PMC: 11405763. DOI: 10.1038/s41598-024-71632-8.


Optimising 4D imaging of fast-oscillating structures using X-ray microtomography with retrospective gating.

Klos A, Bailly L, Rolland du Roscoat S, Orgeas L, Henrich Bernardoni N, Broche L Sci Rep. 2024; 14(1):20499.

PMID: 39227377 PMC: 11372196. DOI: 10.1038/s41598-024-68684-1.


Airspace Diameter Map-A Quantitative Measurement of All Pulmonary Airspaces to Characterize Structural Lung Diseases.

Blaskovic S, Anagnostopoulou P, Borisova E, Schittny D, Donati Y, Haberthur D Cells. 2023; 12(19).

PMID: 37830589 PMC: 10571657. DOI: 10.3390/cells12192375.


Association of x-ray velocimetry (XV) ventilation analysis compared to spirometry.

Kirkness J, Dusting J, Eikelis N, Pirakalathanan P, DeMarco J, Shiao S Front Med Technol. 2023; 5:1148310.

PMID: 37440838 PMC: 10335741. DOI: 10.3389/fmedt.2023.1148310.


References
1.
Galvin I, Drummond G, Nirmalan M . Distribution of blood flow and ventilation in the lung: gravity is not the only factor. Br J Anaesth. 2007; 98(4):420-8. DOI: 10.1093/bja/aem036. View

2.
Kitaoka H, Takaki R, Suki B . A three-dimensional model of the human airway tree. J Appl Physiol (1985). 1999; 87(6):2207-17. DOI: 10.1152/jappl.1999.87.6.2207. View

3.
Yin Y, Choi J, Hoffman E, Tawhai M, Lin C . Simulation of pulmonary air flow with a subject-specific boundary condition. J Biomech. 2010; 43(11):2159-63. PMC: 3034656. DOI: 10.1016/j.jbiomech.2010.03.048. View

4.
Zhao T, Lu W, Yang D, Mutic S, Noel C, Parikh P . Characterization of free breathing patterns with 5D lung motion model. Med Phys. 2009; 36(11):5183-9. PMC: 2774350. DOI: 10.1118/1.3246348. View

5.
Tustison N, Awate S, Cai J, Altes T, Miller G, de Lange E . Pulmonary kinematics from tagged hyperpolarized helium-3 MRI. J Magn Reson Imaging. 2010; 31(5):1236-41. PMC: 2997045. DOI: 10.1002/jmri.22137. View