» Articles » PMID: 35270937

Recent State of Wearable IMU Sensors Use in People Living with Spasticity: A Systematic Review

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2022 Mar 10
PMID 35270937
Authors
Affiliations
Soon will be listed here.
Abstract

Spasticity is a disabling characteristic of neurological disorders, described by a velocity-dependent increase in muscle tone during passive stretch. During the last few years, many studies have been carried out to assess spasticity using wearable IMU (inertial measurements unit) sensors. This review aims to provide an updated framework of the current research on IMUs wearable sensors in people living with spasticity in recent studies published between 2017 and 2021. A total of 322 articles were screened, then finally 10 articles were selected. Results show the lack of homogenization of study procedures and missing apparatus information in some studies. Still, most studies performed adequately on measures of reporting and found that IMUs wearable data was successful in their respective purposes and goals. As IMUs estimate translational and rotational body motions, we believe there is a strong potential for these applications to estimate velocity-dependent exaggeration of stretch reflexes and spasticity-related characteristics in spasticity. This review also proposes new directions of research that should be challenged by larger study groups and could be of interest to both researchers as well as clinicians. The use of IMUs to evaluate spasticity is a promising avenue to provide an objective measurement as compared to non-instrumented traditional assessments.

Citing Articles

Wearable sensors and machine learning fusion-based fall risk prediction in covert cerebral small vessel disease.

Zhou Y, Zhang D, Ji Y, Bu S, Hu X, Zhao C Front Neurosci. 2025; 19:1493988.

PMID: 40046433 PMC: 11879974. DOI: 10.3389/fnins.2025.1493988.


The Effect of Sensor Feature Inputs on Joint Angle Prediction across Simple Movements.

Hollinger D, Schall Jr M, Chen H, Zabala M Sensors (Basel). 2024; 24(11).

PMID: 38894447 PMC: 11175352. DOI: 10.3390/s24113657.


Recent Advances in Wearable Healthcare Devices: From Material to Application.

Luo X, Tan H, Wen W Bioengineering (Basel). 2024; 11(4).

PMID: 38671780 PMC: 11048539. DOI: 10.3390/bioengineering11040358.


A portable system to measure knee extensor spasticity after spinal cord injury.

De Santis D, Perez M J Neuroeng Rehabil. 2024; 21(1):50.

PMID: 38594696 PMC: 11003160. DOI: 10.1186/s12984-024-01326-9.


Surface Electromyography Data Analysis for Evaluation of Physical Exercise Habits between Athletes and Non-Athletes during Indoor Rowing.

Grzejszczak T, Roksela A, Poswiata A, Siemianowicz A, Kielbon A, Mikulski M Sensors (Basel). 2024; 24(6).

PMID: 38544225 PMC: 10975868. DOI: 10.3390/s24061964.


References
1.
Biering-Sorensen F, Nielsen J, Klinge K . Spasticity-assessment: a review. Spinal Cord. 2006; 44(12):708-22. DOI: 10.1038/sj.sc.3101928. View

2.
Arroyo R, Vila C, Clissold S . Retrospective observational study of the management of multiple sclerosis patients with resistant spasticity in Spain: the '5E' study. Expert Rev Pharmacoecon Outcomes Res. 2011; 11(2):205-13. DOI: 10.1586/erp.11.6. View

3.
Pau M, Porta M, Coghe G, Frau J, Lorefice L, Cocco E . Does Multiple Sclerosis Differently Impact Physical Activity in Women and Man? A Quantitative Study Based on Wearable Accelerometers. Int J Environ Res Public Health. 2020; 17(23). PMC: 7729610. DOI: 10.3390/ijerph17238848. View

4.
Bhakta B . Management of spasticity in stroke. Br Med Bull. 2000; 56(2):476-85. DOI: 10.1258/0007142001903111. View

5.
Prill R, Walter M, Krolikowska A, Becker R . A Systematic Review of Diagnostic Accuracy and Clinical Applications of Wearable Movement Sensors for Knee Joint Rehabilitation. Sensors (Basel). 2021; 21(24). PMC: 8707010. DOI: 10.3390/s21248221. View