» Articles » PMID: 35242780

The Improved Catheterization Is Associated With the Deeper Radial Arteries in Ultrasound-Guided Dynamic Needle Tip Positioning Technique

Overview
Specialty General Medicine
Date 2022 Mar 4
PMID 35242780
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: This study aimed to determine the associations between the first-attempt success and arterial depth in ultrasound-guided radial artery catheterization (RAC) with dynamic needle tip positioning (DNTP) technique. This study also aimed to further explore the cut-off depth correlated to improved first-attempt success catheterization in less time.

Methods: The cases undertaken by RAC within the DNTP technique between March 2019 and July 2020 were extracted from our institutional cohort database. Relevant variables were collected, including patients' demographics and catheterized information. Univariable and multivariable logistic regression analyses were performed to determine the association. The receiver operating characteristic (ROC) curve and the Youden index were used to explore the cut-off values of the arterial depth. Categorized cases according to the cut-off values, the Kaplan-Meier analysis, and the log-rank test were used to determine the difference of first-attempt success with limited catheterized time between groups.

Results: In this study, 119 patients were enrolled and 98 achieved first-attempt success. The first-attempt success catheterization was observed to be correlated to arterial depth ( < 0.01, odds ratio 6.47). An optimal cut-off depth of 2.25 mm was found using the Youden index (0.53) by ROC curve (area under curve 0.77). Arterial depth of more than 2.25 mm was correlated to improved first-attempt success catheterization in less time (log-rank < 0.01).

Conclusion: To achieve first-attempt success catheterization using the DNTP technique, an arterial depth of more than 2.25 mm was associated with less catheterized time.

References
1.
Oh E, Lee J, Kwon E, Min J . Simulation-based training using a vessel phantom effectively improved first attempt success and dynamic needle-tip positioning ability for ultrasound-guided radial artery cannulation in real patients: An assessor-blinded randomized controlled study. PLoS One. 2020; 15(6):e0234567. PMC: 7289374. DOI: 10.1371/journal.pone.0234567. View

2.
Bai B, Tian Y, Zhang Y, Yu C, Huang Y . [Factors Contributing Successful Ultrasound-guided Radial Artery Cannulation and Its Complications When Using the Short-axis Out-of-plane Procedure]. Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2020; 42(1):86-90. DOI: 10.3881/j.issn.1000-503X.11617. View

3.
Wei P, Li J, Huang J, Zhang T, Tang W . Radial artery catheterisation pressure monitoring with a closed intravascular catheter system and ultrasound-guided dynamic needle tip positioning technique. Br J Anaesth. 2021; 126(4):e144-e146. PMC: 8176644. DOI: 10.1016/j.bja.2020.12.033. View

4.
Bai B, Tian Y, Zhang Y, Yu C, Huang Y . Dynamic needle tip positioning versus the angle-distance technique for ultrasound-guided radial artery cannulation in adults: a randomized controlled trial. BMC Anesthesiol. 2020; 20(1):231. PMC: 7491138. DOI: 10.1186/s12871-020-01152-1. View

5.
Reusz G, Sarkany P, Gal J, Csomos A . Needle-related ultrasound artifacts and their importance in anaesthetic practice. Br J Anaesth. 2014; 112(5):794-802. DOI: 10.1093/bja/aet585. View