Simulation-based Training Using a Vessel Phantom Effectively Improved First Attempt Success and Dynamic Needle-tip Positioning Ability for Ultrasound-guided Radial Artery Cannulation in Real Patients: An Assessor-blinded Randomized Controlled Study

Overview
Journal PLoS One
Date 2020 Jun 12
PMID 32525955
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Background: We evaluated whether a simulation-based training with a vessel phantom improves the basic skills of a novice required for ultrasound-guided radial artery cannulation in real patients. In addition, we analysed whether repeated simulation training sets with an inter-training interval would accelerate the learning curve.

Methods: From March 2019 to July 2019, twenty-one anesthesiology residents were randomized into either a simulation group (n = 11) or control group (n = 10). Residents performed a total of 84 ultrasound-guided radial artery cannulations in real patients. The simulation group participated in two sets of simulation training on a vessel phantom (10 sessions per set) with a one-month inter-training interval. Trainee's performance proficiency was scored using a developed checklist, and a learning curve for each training set was constructed. To evaluate the effectiveness of our training curriculum in skill transfer, each resident performed four ultrasound-guided radial artery cannulations in real patients. The primary outcome was first attempt success rate and the secondary outcome was dynamic needle-tip positioning ability in real patients.

Results: The first attempt success rate and dynamic needle-tip positioning ability by ultrasound transducer were significantly higher in the simulation group than the control group (81.8% vs. 50%, P = 0.002 and 68.2% vs. 7.5%, P < 0.001, respectively). A reduced number of sessions was required to reach a plateau score on the learning curve in the repeated training set compared in the first-set (7 (5-8) vs. 3 (2-4), P = 0.003, respectively).

Conclusions: Simulation-based training using a vessel phantom effectively improved the first attempt success rate for ultrasound-guided radial artery cannulation in real patients and the dynamic needle-tip positioning ability by ultrasound transducer in novice anesthesiology residents. In addition, repeated training curriculum accelerated the learning curve for recall skill proficiency and reduced inter-individual variability for skill acquisition.

Clinical Trial Registration: Clinical Research Information Service (KCT0003471, Principle investigator: Jeong Jin Min, Date of registration: 06/March/2019).

Citing Articles

An AI-Based Digital Scanner for Detection in Beekeeping.

Scutaru D, Bergonzoli S, Costa C, Violino S, Costa C, Albertazzi S Insects. 2025; 16(1).

PMID: 39859656 PMC: 11766059. DOI: 10.3390/insects16010075.


Teaching Strategies in Interventional Radiology: A Narrative Review of the Literature.

Srinivasan D, Kilic Y, Weston-Petrides G, Patel R, Yazdabadi A, Asadi H Cardiovasc Intervent Radiol. 2024; 48(2):133-141.

PMID: 39461908 PMC: 11790729. DOI: 10.1007/s00270-024-03891-x.


Chinese expert consensus on transradial access in percutaneous peripheral interventions.

Yang M, Jiang S, Wang Y, Meng X, Guo L, Zhang W J Interv Med. 2024; 6(4):145-152.

PMID: 38312127 PMC: 10831370. DOI: 10.1016/j.jimed.2023.10.005.


The Impact of Simulation-Based Training in Cardiovascular Medicine: A Systematic Review.

Kweki A, Sarwar Khan Tharin M, Baptista V, Kenneth E, Rohin F, Scoote M Cureus. 2023; 15(12):e50414.

PMID: 38098737 PMC: 10719544. DOI: 10.7759/cureus.50414.


Effectiveness of ultrasound-guided peripheral arterial cannulation in neonates, including very low birth weight infants who are conventionally difficult-to-cannulate: a case series.

Okada Y, Kido T, Takeuchi S, Hanaki M, Nakamura Y, Nagafuji M Eur J Pediatr. 2023; 183(1):509-512.

PMID: 37930399 DOI: 10.1007/s00431-023-05320-6.


References
1.
Ailon J, Mourad O, Chien V, Saun T, Dev S . Videos in clinical medicine. Ultrasound-guided insertion of a radial arterial catheter. N Engl J Med. 2014; 371(15):e21. DOI: 10.1056/NEJMvcm1213181. View

2.
Troianos C, Hartman G, Glas K, Skubas N, Eberhardt R, Walker J . Special articles: guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society Of Cardiovascular Anesthesiologists. Anesth Analg. 2011; 114(1):46-72. DOI: 10.1213/ANE.0b013e3182407cd8. View

3.
Hseino H, Nugent E, Lee M, Hill A, Neary P, Tierney S . Skills transfer after proficiency-based simulation training in superficial femoral artery angioplasty. Simul Healthc. 2012; 7(5):274-81. DOI: 10.1097/SIH.0b013e31825b6308. View

4.
Karni A, Meyer G, Jezzard P, Adams M, Turner R, Ungerleider L . The acquisition of skilled motor performance: fast and slow experience-driven changes in primary motor cortex. Proc Natl Acad Sci U S A. 1998; 95(3):861-8. PMC: 33809. DOI: 10.1073/pnas.95.3.861. View

5.
de Oliveira Filho G, Helayel P, da Conceicao D, Garzel I, Pavei P, Sperotto Ceccon M . Learning curves and mathematical models for interventional ultrasound basic skills. Anesth Analg. 2008; 106(2):568-73, table of contents. DOI: 10.1213/ane.0b013e3181605412. View