Commissioning a Multileaf Collimator Virtual Cone for the Stereotactic Radiosurgery of Trigeminal Neuralgia

Overview
Date 2022 Feb 14
PMID 35157356
Authors
Affiliations
Soon will be listed here.
Abstract

A multileaf collimator (MLC), virtual-cone treatment technique has been commissioned for trigeminal neuralgia (TGN) at Tri-Cities Cancer Center (TCCC). This novel technique was initially developed at the University of Alabama in Birmingham (UAB); it is designed to produce a spherical dose profile similar to a fixed, 5-mm conical collimator distribution. Treatment is delivered with a 10-MV flattening-filter-free (FFF) beam using a high-definition MLC on a Varian Edge linear accelerator. Absolute dose output and profile measurements were performed in a 20 × 20 × 14 cm solid-water phantom using an Exradin W2 scintillation detector and Gafchromic EBT3 film. Dose output constancy for the virtual cone was evaluated over 6 months using an Exradin A11 parallel plate chamber. The photo-neutron dose generated by these treatments was assessed at distances of 50 and 100 cm from isocenter using a Ludlum Model 30-7 Series Neutron Meter. TGN treatments at TCCC have been previously delivered at 6-MV FFF using a 5-mm stereotactic cone. To assess the dosimetric impact of using a virtual cone, eight patients previously treated for TGN with a 5-mm cone were re-planned using a virtual cone. Seven patients have now been treated for TGN using a virtual cone at TCCC. Patient-specific quality assurance was performed for each patient using Gafchromic EBT-XD film inside a Standard Imaging Stereotactic Dose Verification Phantom. The commissioning results demonstrate that the virtual-cone dosimetry, first described at UAB, is reproducible on a second Edge linear accelerator at an independent clinical site. The virtual cone is a credible alternative to a physical, stereotactic cone for the treatment of TGN at TCCC.

Citing Articles

Viability of the virtual cone technique using a fixed small multi-leaf collimator field for stereotactic radiosurgery of trigeminal neuralgia.

Neupane T, Shang C, Kassel M, Muhammad W, Leventouri T, Williams T J Appl Clin Med Phys. 2023; 24(12):e14148.

PMID: 37722766 PMC: 10691631. DOI: 10.1002/acm2.14148.


Commissioning of Aktina SRS cones and dosimetric validation of the RayStation photon Monte Carlo dose calculation algorithm.

Schofield A, Newall M, Inwood D, Downes S, Corde S Phys Eng Sci Med. 2023; 46(4):1503-1518.

PMID: 37603132 PMC: 10703943. DOI: 10.1007/s13246-023-01315-7.


Overview of medical physics education and research programs in a non-academic environment.

Fagerstrom J, Brown T, Kaurin D, Mahendra S, Zaini M J Appl Clin Med Phys. 2023; 24(10):e14124.

PMID: 37602785 PMC: 10562031. DOI: 10.1002/acm2.14124.


Radiosurgical treatment of solitary brain metastases using virtual cones with a standard multileaf collimator.

Lobb E J Appl Clin Med Phys. 2022; 24(4):e13882.

PMID: 36576722 PMC: 10113701. DOI: 10.1002/acm2.13882.


Characterization of the Plastic Scintillator Detector System Exradin W2 in a High Dose Rate Flattening-Filter-Free Photon Beam.

Thrower S, Prajapati S, Holmes S, Schuler E, Beddar S Sensors (Basel). 2022; 22(18).

PMID: 36146135 PMC: 9505273. DOI: 10.3390/s22186785.


References
1.
Leon-Marroquin E, Mulrow D, Darafsheh A, Khan R . Response characterization of EBT-XD radiochromic films in megavoltage photon and electron beams. Med Phys. 2019; 46(9):4246-4256. DOI: 10.1002/mp.13708. View

2.
Popple R, Wu X, Brezovich I, Markert J, Guthrie B, Thomas E . The virtual cone: A novel technique to generate spherical dose distributions using a multileaf collimator and standardized control-point sequence for small target radiation surgery. Adv Radiat Oncol. 2018; 3(3):421-430. PMC: 6127970. DOI: 10.1016/j.adro.2018.02.011. View

3.
Brown T, Ayers R, Popple R . Commissioning a multileaf collimator virtual cone for the stereotactic radiosurgery of trigeminal neuralgia. J Appl Clin Med Phys. 2022; 23(5):e13562. PMC: 9121036. DOI: 10.1002/acm2.13562. View

4.
Marroquin E, Herrera Gonzalez J, Camacho Lopez M, Villarreal Barajas J, Garcia-Garduno O . Evaluation of the uncertainty in an EBT3 film dosimetry system utilizing net optical density. J Appl Clin Med Phys. 2016; 17(5):466-481. PMC: 5874103. DOI: 10.1120/jacmp.v17i5.6262. View

5.
Glasgow G . Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities. Med Phys. 2017; 33(9):3578. DOI: 10.1118/1.2336250. View