» Articles » PMID: 3514627

Craniocervical Instability Treated by Contoured Loop Fixation

Overview
Date 1986 Mar 1
PMID 3514627
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

Rigid posterior fixation of the skull to the third, fourth and fifth cervical vertebrae was achieved in three patients who, as a result of operation, had gross instability of the craniocervical junction. An anatomically contoured steel loop was secured to the occiput via small burr holes and to the vertebrae by sublaminar wiring. This technique has the advantage over bone grafting, either alone or with cement, in that it affords rigid stabilisation, allows early mobilisation and may contribute to eventual bony fusion.

Citing Articles

Surgical strategies in the management of atlantoaxial dislocation in Down syndrome.

Joseph V, Ganesh S, Panicker T J Craniovertebr Junction Spine. 2024; 15(1):53-60.

PMID: 38644917 PMC: 11029113. DOI: 10.4103/jcvjs.jcvjs_171_23.


Morphometric Trajectory Analysis for Occipital Condyle Screws.

Du Y, Li S, Yang W, Wang X, Bi Y, Dong J Orthop Surg. 2020; 12(3):931-937.

PMID: 32495510 PMC: 7307246. DOI: 10.1111/os.12700.


Surgical, clinical, and radiological outcomes of occipitocervical fusion using the plate-screw-rod system with allograft in craniocervical instability.

Upadhyaya M, Jain S, Kire N, Merchant Z, Kundnani V, Patel A J Craniovertebr Junction Spine. 2020; 10(4):216-223.

PMID: 32089614 PMC: 7008657. DOI: 10.4103/jcvjs.JCVJS_87_19.


Complex spine deformities in young patients with severe osteogenesis imperfecta: current concepts review.

Castelein R, Hasler C, Helenius I, Ovadia D, Yazici M J Child Orthop. 2019; 13(1):22-32.

PMID: 30838072 PMC: 6376432. DOI: 10.1302/1863-2548.13.180185.


Additional Surgical Method Aimed to Increase Distractive Force during Occipitocervical Stabilization : Technical Note.

Antar V, Turk O J Korean Neurosurg Soc. 2018; 61(2):277-281.

PMID: 29526072 PMC: 5853194. DOI: 10.3340/jkns.2017.0197.