Multispectral Imaging Using Fluorescent Properties of Indocyanine Green and Methylene Blue in Colorectal Surgery-Initial Experience

Overview
Journal J Clin Med
Specialty General Medicine
Date 2022 Jan 21
PMID 35054062
Authors
Affiliations
Soon will be listed here.
Abstract

Image-guided surgery is becoming a new tool in colorectal surgery. Intraoperative visualisation of different structures using fluorophores helps during various steps of operations. In our report, we used two fluorophores-indocyanine green (ICG), and methylene blue (MB)-during different steps of colorectal surgery, using one camera system for two separate near-infrared wavelengths. Twelve patients who underwent complex open or laparoscopic colorectal surgeries were enrolled. Intravenous injections of MB and ICG at different time points were administered. Visualisation of intraoperative ureter position and fluorescent angiography for optimal anastomosis was performed. A retrospective analysis of patients treated in our departments during 2020 was performed, and data about ureter injury and anastomotic site complications were collected. Intraoperative localisation of ureters with MB under fluorescent light was possible in 11 patients. The mean signal-to-background ratio was 1.58 ± 0.71. Fluorescent angiography before performing anastomosis using ICG was successful in all 12 patients, and none required a change in position of the planned colon resection for anastomosis. The median signal-to-background ratios was 1.25 (IQR: 1.22-1.89). Across both centres, iatrogenic injury of the ureter was found in 0.4% of cases, and complications associated with anastomosis was found in 5.5% of cases. Our study showed a substantial opportunity for using two different fluorophores in colorectal surgery, whereby the visualisation of one will not change the possible quantification analysis of the other. Using two separate dyes during one procedure may help in optimisation of the fluorescent properties of both dyes when using them for different applications. Visualisation of different structures by different fluorophores seems to be the future of image-guided surgery, and shows progress in optical technologies used in image-guided surgery.

Citing Articles

Initial experience of ureteric visualization using methylene blue during laparoscopy for gynecological surgery.

Shao R, Shen F, Soleymani Majd H, Qin X, Yao D, Long Y Front Surg. 2024; 11:1387038.

PMID: 39092154 PMC: 11291209. DOI: 10.3389/fsurg.2024.1387038.


Update on near infrared imaging technology: indocyanine green and near infrared technology in the treatment of gynecologic cancers.

Manning-Geist B, Obermair A, Broach V, Leitao M, Zivanovic O, Abu-Rustum N Int J Gynecol Cancer. 2024; 34(3):416-420.

PMID: 38438171 PMC: 10962647. DOI: 10.1136/ijgc-2023-004583.


Fluorescent Probes for Imaging in Humans: Where Are We Now?.

Seah D, Cheng Z, Vendrell M ACS Nano. 2023; 17(20):19478-19490.

PMID: 37787658 PMC: 10604082. DOI: 10.1021/acsnano.3c03564.


Indocyanine Green (ICG) and Colorectal Surgery: A Literature Review on Qualitative and Quantitative Methods of Usage.

Simion L, Ionescu S, Chitoran E, Rotaru V, Cirimbei C, Madge O Medicina (Kaunas). 2023; 59(9).

PMID: 37763651 PMC: 10536016. DOI: 10.3390/medicina59091530.


Simultaneous fluorescence imaging of bowel perfusion and ureter delineation using methylene blue: a demonstration in a porcine model.

Heuvelings D, Al-Difaie Z, Scheepers M, Okamoto N, Diana M, Stassen L Surg Endosc. 2023; 37(9):6779-6790.

PMID: 37253870 PMC: 10462514. DOI: 10.1007/s00464-023-10142-6.


References
1.
Barnes T, Hompes R, Birks J, Mortensen N, Jones O, Lindsey I . Methylene blue fluorescence of the ureter during colorectal surgery. Surg Endosc. 2018; 32(9):4036-4043. PMC: 6096537. DOI: 10.1007/s00464-018-6219-8. View

2.
Selvam S, Sarkar I . Bile salt induced solubilization of methylene blue: Study on methylene blue fluorescence properties and molecular mechanics calculation. J Pharm Anal. 2018; 7(1):71-75. PMC: 5686871. DOI: 10.1016/j.jpha.2016.07.006. View

3.
de Gooyer J, Elekonawo F, Bos D, van der Post R, Pelegrin A, Framery B . Multimodal CEA-Targeted Image-Guided Colorectal Cancer Surgery using In-Labeled SGM-101. Clin Cancer Res. 2020; 26(22):5934-5942. DOI: 10.1158/1078-0432.CCR-20-2255. View

4.
Al-Awadi K, Kehinde E, Al-Hunayan A, Al-Khayat A . Iatrogenic ureteric injuries: incidence, aetiological factors and the effect of early management on subsequent outcome. Int Urol Nephrol. 2005; 37(2):235-41. DOI: 10.1007/s11255-004-7970-4. View

5.
Slooter M, Janssen A, Bemelman W, Tanis P, Hompes R . Currently available and experimental dyes for intraoperative near-infrared fluorescence imaging of the ureters: a systematic review. Tech Coloproctol. 2019; 23(4):305-313. PMC: 6536635. DOI: 10.1007/s10151-019-01973-4. View