» Articles » PMID: 34782637

An Automated Retrospective VAE-surveillance Tool for Future Quality Improvement Studies

Overview
Journal Sci Rep
Specialty Science
Date 2021 Nov 16
PMID 34782637
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Ventilator-associated pneumonia (VAP) is a frequent complication of mechanical ventilation and is associated with substantial morbidity and mortality. Accurate diagnosis of VAP relies in part on subjective diagnostic criteria. Surveillance according to ventilator-associated event (VAE) criteria may allow quick and objective benchmarking. Our objective was to create an automated surveillance tool for VAE tiers I and II on a large data collection, evaluate its diagnostic accuracy and retrospectively determine the yearly baseline VAE incidence. We included all consecutive intensive care unit admissions of patients with mechanical ventilation at Bern University Hospital, a tertiary referral center, from January 2008 to July 2016. Data was automatically extracted from the patient data management system and automatically processed. We created and implemented an application able to automatically analyze respiratory and relevant medication data according to the Centers for Disease Control protocol for VAE-surveillance. In a subset of patients, we compared the accuracy of automated VAE surveillance according to CDC criteria to a gold standard (a composite of automated and manual evaluation with mediation for discrepancies) and evaluated the evolution of the baseline incidence. The study included 22'442 ventilated admissions with a total of 37'221 ventilator days. 592 ventilator-associated events (tier I) occurred; of these 194 (34%) were of potentially infectious origin (tier II). In our validation sample, automated surveillance had a sensitivity of 98% and specificity of 100% in detecting VAE compared to the gold standard. The yearly VAE incidence rate ranged from 10.1-22.1 per 1000 device days and trend showed a decrease in the yearly incidence rate ratio of 0.96 (95% CI, 0.93-1.00, p = 0.03). This study demonstrated that automated VAE detection is feasible, accurate and reliable and may be applied on a large, retrospective sample and provided insight into long-term institutional VAE incidences. The surveillance tool can be extended to other centres and provides VAE incidences for performing quality control and intervention studies.

Citing Articles

Enhancing ICU Outcomes Through Intelligent Monitoring Systems: A Comparative Study on Ventilator-Associated Events.

Liu J, Kang M, Lin H, Liu S J Clin Med. 2024; 13(21).

PMID: 39518741 PMC: 11546999. DOI: 10.3390/jcm13216600.


Ceftazidime/avibactam combined with colistin: a novel attempt to treat carbapenem-resistant Gram-negative bacilli infection.

Zheng Z, Shao Z, Lu L, Tang S, Shi K, Gong F BMC Infect Dis. 2023; 23(1):709.

PMID: 37864200 PMC: 10589954. DOI: 10.1186/s12879-023-08715-w.


A Method to Explore Variations of Ventilator-Associated Event Surveillance Definitions in Large Critical Care Databases in the United States.

Wong A, Kim H, Charpignon M, Carvalho L, Monares-Zepeda E, Madushani R Crit Care Explor. 2022; 4(11):e0790.

PMID: 36406886 PMC: 9668560. DOI: 10.1097/CCE.0000000000000790.

References
1.
Lilly C, Landry K, Sood R, Dunnington C, Ellison 3rd R, Bagley P . Prevalence and test characteristics of national health safety network ventilator-associated events. Crit Care Med. 2014; 42(9):2019-28. DOI: 10.1097/CCM.0000000000000396. View

2.
Melsen W, Rovers M, Groenwold R, Bergmans D, Camus C, Bauer T . Attributable mortality of ventilator-associated pneumonia: a meta-analysis of individual patient data from randomised prevention studies. Lancet Infect Dis. 2013; 13(8):665-71. DOI: 10.1016/S1473-3099(13)70081-1. View

3.
Valles J, Pobo A, Garcia-Esquirol O, Mariscal D, Real J, Fernandez R . Excess ICU mortality attributable to ventilator-associated pneumonia: the role of early vs late onset. Intensive Care Med. 2007; 33(8):1363-8. DOI: 10.1007/s00134-007-0721-0. View

4.
Horan T, Andrus M, Dudeck M . CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control. 2008; 36(5):309-32. DOI: 10.1016/j.ajic.2008.03.002. View

5.
Stevens J, Silva G, Gillis J, Novack V, Talmor D, Klompas M . Automated surveillance for ventilator-associated events. Chest. 2014; 146(6):1612-1618. PMC: 4251620. DOI: 10.1378/chest.13-2255. View