» Articles » PMID: 24810522

Prevalence and Test Characteristics of National Health Safety Network Ventilator-associated Events

Overview
Journal Crit Care Med
Date 2014 May 10
PMID 24810522
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The primary aim of the study was to measure the test characteristics of the National Health Safety Network ventilator-associated event/ventilator-associated condition constructs for detecting ventilator-associated pneumonia. Its secondary aims were to report the clinical features of patients with National Health Safety Network ventilator-associated event/ventilator-associated condition, measure costs of surveillance, and its susceptibility to manipulation.

Design: Prospective cohort study.

Setting: Two inpatient campuses of an academic medical center.

Patients: Eight thousand four hundred eight mechanically ventilated adults discharged from an ICU.

Interventions: None.

Measurements And Main Results: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs detected less than a third of ventilator-associated pneumonia cases with a sensitivity of 0.325 and a positive predictive value of 0.07. Most National Health Safety Network ventilator-associated event/ventilator-associated condition cases (93%) did not have ventilator-associated pneumonia or other hospital-acquired complications; 71% met the definition for acute respiratory distress syndrome. Similarly, most patients with National Health Safety Network probable ventilator-associated pneumonia did not have ventilator-associated pneumonia because radiographic criteria were not met. National Health Safety Network ventilator-associated event/ventilator-associated condition rates were reduced 93% by an unsophisticated manipulation of ventilator management protocols.

Conclusions: The National Health Safety Network ventilator-associated event/ventilator-associated condition constructs failed to detect many patients who had ventilator-associated pneumonia, detected many cases that did not have a hospital complication, and were susceptible to manipulation. National Health Safety Network ventilator-associated event/ventilator-associated condition surveillance did not perform as well as ventilator-associated pneumonia surveillance and had several undesirable characteristics.

Citing Articles

Surveillance of ventilator associated pneumonia in a network of indian hospitals using modified definitions: a pilot study.

Mathur P, Ningombam A, Soni K, Aggrawal R, Singh K, Samanta P Lancet Reg Health Southeast Asia. 2024; 28:100450.

PMID: 39130755 PMC: 11315213. DOI: 10.1016/j.lansea.2024.100450.


Impact of a national collaborative project to improve the care of mechanically ventilated patients.

Arabi Y, Al Aseri Z, Alsaawi A, Al Khathaami A, Al Qasim E, Alzahrani A PLoS One. 2023; 18(1):e0280744.

PMID: 36716310 PMC: 9886257. DOI: 10.1371/journal.pone.0280744.


An automated retrospective VAE-surveillance tool for future quality improvement studies.

Wolffers O, Faltys M, Thomann J, Jakob S, Marschall J, Merz T Sci Rep. 2021; 11(1):22264.

PMID: 34782637 PMC: 8593155. DOI: 10.1038/s41598-021-01402-3.


A scoping review of registry captured indicators for evaluating quality of critical care in ICU.

Jawad I, Rashan S, Sigera C, Salluh J, Dondorp A, Haniffa R J Intensive Care. 2021; 9(1):48.

PMID: 34353360 PMC: 8339165. DOI: 10.1186/s40560-021-00556-6.


Concordance between the National Healthcare Safety Network (NHSN) Surveillance Criteria and Clinical Pulmonary Infection Score (CPIS) Criteria for Diagnosis of Ventilator-associated Pneumonia (VAP).

Gunalan A, Sistla S, Sastry A, Venkateswaran R Indian J Crit Care Med. 2021; 25(3):296-298.

PMID: 33790510 PMC: 7991760. DOI: 10.5005/jp-journals-10071-23753.