» Articles » PMID: 34679536

A Novel Rapid Test to Detect Anti-SARS-CoV-2 N Protein IgG Based on Shear Horizontal Surface Acoustic Wave (SH-SAW)

Overview
Specialty Radiology
Date 2021 Oct 23
PMID 34679536
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

Since the Coronavirus disease 2019 (COVID-19) pandemic outbreak, many methods have been used to detect antigens or antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), including viral culture, nucleic acid test, and immunoassay. The shear-horizontal surface acoustic wave (SH-SAW) biosensor is a novel pathogen detection platform with the advantages of high sensitivity and short detection time. The objective of this study is to develop a SH-SAW biosensor to detect the anti-SARS-CoV-2 nucleocapsid antibody. The rabbit sera collected from rabbits on different days after SARS-CoV-2 N protein injection were evaluated by SH-SAW biosensor and enzyme-linked immunosorbent assay (ELISA). The results showed that the SH-SAW biosensor achieved a high correlation coefficient (R = 0.9997) with different concentrations (34.375-1100 ng/mL) of the "spike-in" anti-N protein antibodies. Compared to ELISA, the SH-SAW biosensor has better sensitivity and can detect anti-N protein IgG signals earlier than ELISA on day 6 ( < 0.05). Overall, in this study, we demonstrated that the SH-SAW biosensor is a promising platform for rapid in vitro diagnostic (IVD) testing, especially for antigen or antibody testing.

Citing Articles

Tracking the Risk of Cardiovascular Disease after Almond and Oat Milk Intervene or Statin Medication with a Powerful Reflex SH-SAW POCT Platform.

Cheng C, Yatsuda H, Chen H, Young G, Liu S, Wang R Sensors (Basel). 2024; 24(20).

PMID: 39459999 PMC: 11511040. DOI: 10.3390/s24206517.


Dual-Mode Solidly Mounted Resonator-Based Sensor for Temperature and Humidity Detection and Discrimination.

Carmona-Cejas J, Mirea T, Hervas-Garcia R, Olivares J, Clement M Sensors (Basel). 2024; 24(9).

PMID: 38732983 PMC: 11086162. DOI: 10.3390/s24092877.


Low-noise fluorescent detection of cardiac troponin I in human serum based on surface acoustic wave separation.

Chen X, Zhang C, Liu X, Dong Y, Meng H, Qin X Microsyst Nanoeng. 2023; 9:141.

PMID: 37954038 PMC: 10632424. DOI: 10.1038/s41378-023-00600-5.


The Recent Development of Acoustic Sensors as Effective Chemical Detecting Tools for Biological Cells and Their Bioactivities.

Gouda M, Ghazzawy H, Alqahtani N, Li X Molecules. 2023; 28(12).

PMID: 37375410 PMC: 10304203. DOI: 10.3390/molecules28124855.


Application of Shear Horizontal Surface Acoustic Wave (SH-SAW) Immunosensor in Point-of-Care Diagnosis.

Cheng C, Yatsuda H, Goto M, Kondoh J, Liu S, Wang R Biosensors (Basel). 2023; 13(6).

PMID: 37366970 PMC: 10296254. DOI: 10.3390/bios13060605.


References
1.
Hussein H, Hassan R, Chino M, Febbraio F . Point-of-Care Diagnostics of COVID-19: From Current Work to Future Perspectives. Sensors (Basel). 2020; 20(15). PMC: 7435936. DOI: 10.3390/s20154289. View

2.
Tizaoui K, Zidi I, Lee K, Abou Ghayda R, Hong S, Li H . Update of the current knowledge on genetics, evolution, immunopathogenesis, and transmission for coronavirus disease 19 (COVID-19). Int J Biol Sci. 2020; 16(15):2906-2923. PMC: 7545713. DOI: 10.7150/ijbs.48812. View

3.
Qiu G, Gai Z, Tao Y, Schmitt J, Kullak-Ublick G, Wang J . Dual-Functional Plasmonic Photothermal Biosensors for Highly Accurate Severe Acute Respiratory Syndrome Coronavirus 2 Detection. ACS Nano. 2020; 14(5):5268-5277. DOI: 10.1021/acsnano.0c02439. View

4.
Gitman M, Shaban M, Paniz-Mondolfi A, Sordillo E . Laboratory Diagnosis of SARS-CoV-2 Pneumonia. Diagnostics (Basel). 2021; 11(7). PMC: 8306256. DOI: 10.3390/diagnostics11071270. View

5.
Kano K, Yatsuda H, Kondoh J . Evaluation of Shear Horizontal Surface Acoustic Wave Biosensors Using "Layer Parameter" Obtained from Sensor Responses during Immunoreaction. Sensors (Basel). 2021; 21(14). PMC: 8309872. DOI: 10.3390/s21144924. View