» Articles » PMID: 34615977

Effect of Gamma Irradiation on Filtering Facepiece Respirators and SARS-CoV-2 Detection

Overview
Journal Sci Rep
Specialty Science
Date 2021 Oct 7
PMID 34615977
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

To cope with the shortage of filtering facepiece respirators (FFRs) during the coronavirus (COVID-19) pandemic, healthcare institutions were forced to reuse FFRs after applying different decontamination methods including gamma-irradiation (GIR). The aim of this study was to evaluate the effect of GIR on the filtration efficiency (FE) of FFRs and on SARS-CoV-2 detection. The FE of 2 FFRs types (KN95 and N95-3 M masks) was assessed at different particle sizes (0.3-5 µm) following GIR (0-15 kGy) delivered at either typical (1.65 kGy/h) or low (0.5088 kGy/h) dose rates. The detection of two SARS-CoV-2 RNA genes (E and RdRp4) following GIR (0-50 kGy) was carried out using RT-qPCR assay. Both masks showed an overall significant (P < 0.001) reduction in FE with increased GIR doses. No significant differences were observed between GIR dose rates on FE. The GIR exhibited significant increases (P ≤ 0.001) in the cycle threshold values (ΔCt) of both genes, with no detection following high doses. In conclusion, complete degradation of SARS-CoV-2 RNA can be achieved by high GIR (≥ 30 kGy), suggesting its potential use in FFRs decontamination. However, GIR exhibited adverse effects on FE in dose- and particle size-dependent manners, rendering its use to decontaminate FFRs debatable.

Citing Articles

Engineering Materials and Devices for the Prevention, Diagnosis, and Treatment of COVID-19 and Infectious Diseases.

Soto J, Linsley C, Song Y, Chen B, Fang J, Neyyan J Nanomaterials (Basel). 2023; 13(17).

PMID: 37686965 PMC: 10490511. DOI: 10.3390/nano13172455.


Quantitative determination of the electron beam radiation dose for SARS-CoV-2 inactivation to decontaminate frozen food packaging.

Wang Z, Liang Z, Wei R, Wang H, Cheng F, Liu Y Virol Sin. 2022; 37(6):823-830.

PMID: 36309306 PMC: 9605788. DOI: 10.1016/j.virs.2022.10.007.


Disinfection and decontamination in the context of SARS-CoV-2-specific data.

Cimolai N J Med Virol. 2022; 94(10):4654-4668.

PMID: 35758523 PMC: 9350315. DOI: 10.1002/jmv.27959.


Multifunctional Carbon Fibers from Chemical Upcycling of Mask Waste.

Robertson M, Guillen Obando A, Emery J, Qiang Z ACS Omega. 2022; 7(14):12278-12287.

PMID: 35449951 PMC: 9016816. DOI: 10.1021/acsomega.2c00711.

References
1.
Ohshima H, Iida Y, Matsuda A, Kuwabara M . Damage induced by hydroxyl radicals generated in the hydration layer of gamma-irradiated frozen aqueous solution of DNA. J Radiat Res. 1996; 37(3):199-207. DOI: 10.1269/jrr.37.199. View

2.
Al-Hadyan K, Alsbeih G, Nobah A, Lindstrom J, Falatah S, Faran N . In-House Filtration Efficiency Assessment of Vapor Hydrogen Peroxide Decontaminated Filtering Facepiece Respirators (FFRs). Int J Environ Res Public Health. 2021; 18(13). PMC: 8297238. DOI: 10.3390/ijerph18137169. View

3.
Rodriguez-Martinez C, Sossa-Briceno M, Cortes J . Decontamination and reuse of N95 filtering facemask respirators: A systematic review of the literature. Am J Infect Control. 2020; 48(12):1520-1532. PMC: 7342027. DOI: 10.1016/j.ajic.2020.07.004. View

4.
Korystov YuN . Contributions of the direct and indirect effects of ionizing radiation to reproductive cell death. Radiat Res. 1992; 129(2):228-34. View

5.
Beniac D, Andonov A, Grudeski E, Booth T . Architecture of the SARS coronavirus prefusion spike. Nat Struct Mol Biol. 2006; 13(8):751-2. PMC: 7097490. DOI: 10.1038/nsmb1123. View