» Articles » PMID: 34526053

Assessing the Usability of Wearable Devices to Measure Gait and Physical Activity in Chronic Conditions: a Systematic Review

Overview
Publisher Biomed Central
Date 2021 Sep 16
PMID 34526053
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The World Health Organisation's global strategy for digital health emphasises the importance of patient involvement. Understanding the usability and acceptability of wearable devices is a core component of this. However, usability assessments to date have focused predominantly on healthy adults. There is a need to understand the patient perspective of wearable devices in participants with chronic health conditions.

Methods: A systematic review was conducted to identify any study design that included a usability assessment of wearable devices to measure mobility, through gait and physical activity, within five cohorts with chronic conditions (Parkinson's disease [PD], multiple sclerosis [MS], congestive heart failure, [CHF], chronic obstructive pulmonary disorder [COPD], and proximal femoral fracture [PFF]).

Results: Thirty-seven studies were identified. Substantial heterogeneity in the quality of reporting, the methods used to assess usability, the devices used, and the aims of the studies precluded any meaningful comparisons. Questionnaires were used in the majority of studies (70.3%; n = 26) with a reliance on intervention specific measures (n = 16; 61.5%). For those who used interviews (n = 17; 45.9%), no topic guides were provided, while methods of analysis were not reported in over a third of studies (n = 6; 35.3%).

Conclusion: Usability of wearable devices is a poorly measured and reported variable in chronic health conditions. Although the heterogeneity in how these devices are implemented implies acceptance, the patient voice should not be assumed. In the absence of being able to make specific usability conclusions, the results of this review instead recommends that future research needs to: (1) Conduct usability assessments as standard, irrespective of the cohort under investigation or the type of study undertaken. (2) Adhere to basic reporting standards (e.g. COREQ) including the basic details of the study. Full copies of any questionnaires and interview guides should be supplied through supplemental files. (3) Utilise mixed methods research to gather a more comprehensive understanding of usability than either qualitative or quantitative research alone will provide. (4) Use previously validated questionnaires alongside any intervention specific measures.

Citing Articles

Usefulness of the LAVITA Telemonitoring System in Patients With Heart Failure - A Feasibility Study.

Noguchi M, Nomura A, Takeji Y, Shimojima M, Yoshida S, Kitano T Circ Rep. 2025; 7(2):106-112.

PMID: 39931711 PMC: 11807691. DOI: 10.1253/circrep.CR-24-0099.


Exploring the Effect of Sampling Frequency on Real-World Mobility, Sedentary Behaviour, Physical Activity and Sleep Outcomes Measured with Wearable Devices in Rheumatoid Arthritis: Feasibility, Usability and Practical Considerations.

Sarvestan J, Baker K, Del Din S Bioengineering (Basel). 2025; 12(1).

PMID: 39851290 PMC: 11762398. DOI: 10.3390/bioengineering12010018.


Human Factors, Human-Centered Design, and Usability of Sensor-Based Digital Health Technologies: Scoping Review.

Tandon A, Cobb B, Centra J, Izmailova E, Manyakov N, McClenahan S J Med Internet Res. 2024; 26:e57628.

PMID: 39546781 PMC: 11607562. DOI: 10.2196/57628.


The acceptability of wearable technology for long-term respiratory disease: A cross-sectional survey.

Shah A, Saigal A, Althobiani M, Hurst J, Mandal S Heliyon. 2024; 10(16):e35474.

PMID: 39220892 PMC: 11363846. DOI: 10.1016/j.heliyon.2024.e35474.


Assessing the clinical utility of inertial sensors for home monitoring in Parkinson's disease: a comprehensive review.

Sapienza S, Tsurkalenko O, Giraitis M, Castro Mejia A, Zelimkhanov G, Schwaninger I NPJ Parkinsons Dis. 2024; 10(1):161.

PMID: 39164257 PMC: 11335938. DOI: 10.1038/s41531-024-00755-6.


References
1.
James S, Lucchesi L, Bisignano C, Castle C, Dingels Z, Fox J . The global burden of falls: global, regional and national estimates of morbidity and mortality from the Global Burden of Disease Study 2017. Inj Prev. 2020; 26(Supp 1):i3-i11. PMC: 7571347. DOI: 10.1136/injuryprev-2019-043286. View

2.
Adams J, Dinesh K, Xiong M, Tarolli C, Sharma S, Sheth N . Multiple Wearable Sensors in Parkinson and Huntington Disease Individuals: A Pilot Study in Clinic and at Home. Digit Biomark. 2020; 1(1):52-63. PMC: 7015372. DOI: 10.1159/000479018. View

3.
Moher D, Liberati A, Tetzlaff J, Altman D . Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement. Open Med. 2011; 3(3):e123-30. PMC: 3090117. View

4.
Floegel T, Allen K, Buman M . A pilot study examining activity monitor use in older adults with heart failure during and after hospitalization. Geriatr Nurs. 2018; 40(2):185-189. DOI: 10.1016/j.gerinurse.2018.10.001. View

5.
van der Weegen S, Verwey R, Tange H, Spreeuwenberg M, de Witte L . Usability testing of a monitoring and feedback tool to stimulate physical activity. Patient Prefer Adherence. 2014; 8:311-22. PMC: 3962312. DOI: 10.2147/PPA.S57961. View