» Articles » PMID: 34386278

Accuracy of the SWAY Mobile Cognitive Assessment Application

Overview
Date 2021 Aug 13
PMID 34386278
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Mobile electronic devices have become integral tools in addressing the need for portable assessment of cognitive function following neurocognitive/motor injury. SWAY Medical, Inc., has employed mobile device motion-based technology in the SWAY Cognitive Assessment (SWAY CA) application to assess cognitive function.

Purpose: The purpose of this study was to assess whether the SWAY CA application (reaction time, impulse control and inspective time) was able to reliably operate on different mobile devices and operating systems (iOS, Android). The study further sought to assess the validity of the SWAY CA application against the FDA approved ImPACT QT mobile device application.

Study Design: Original Research, observational study of validity.

Methods: 88 healthy, young adults, 18 to 48 years (= 22.09 ± =4.47 years) completed four, randomized and counter-balanced, reaction time tests (2- SWAY RT, 2- ImPACT QT) using different operating systems (iOS, Android) of 4 randomly assigned mobile devices.

Results: ANOVAs reported the SWAY CA application (reaction time, impulse control, inspection time) operated reliably with iPhone 6S, Samsung Galaxy S9, and iPad Pro 5 mobile devices ( > 0.05), respectively. Google Pixel 3 reliability with SWAY CA application remains undetermined. SWAY CA simple reaction motion measures were in agreement ( = -0.46 to 0.22, ≤ 0.05) with several ImPACT QT reaction time measures. SWAY CA impulse control and inspection time measures are weakly correlated ( = -0.25 to -0.46, ≤ 0.05) with five ImPACT QT reaction time measures.

Conclusion: The motion-based SWAY CA mobile device application appears to reliably operate when being administered on different mobile devices and software operating systems. Furthermore, the SWAY CA application appears to be comparable to the ImPACT QT and serve as a valid tool for assessing reaction time measures.

Level Of Evidence: Level 2b (observational study of validity).

Citing Articles

Immediate Effects of Whole Body Vibration on Proprioception and Upper Extremity Reaction Speed in Young Adult Students.

Maden C, Yigit S, Karabulut D, Kavak F, Yildirim H, Elpeze G Med Lav. 2024; 115(6):e2024045.

PMID: 39697080 PMC: 11734632. DOI: 10.23749/mdl.v115i6.16523.


Effect of ketone monoester supplementation on elite operators' mountaineering training.

Miyatsu T, McAdam J, Coleman K, Chappe E, Tuggle S, McClure T Front Physiol. 2024; 15:1411421.

PMID: 39290617 PMC: 11405315. DOI: 10.3389/fphys.2024.1411421.


Empowering sickle cell disease care: the rise of in Sub-Saharan Africa for enhanced patient's perspectives.

Boma P, Ngoy S, Panda J, Bonnechere B Front Rehabil Sci. 2024; 5:1388855.

PMID: 38994332 PMC: 11236801. DOI: 10.3389/fresc.2024.1388855.


Pupillometry as a new window to player fatigue? A glimpse inside the eyes of a Euro Cup Women's Basketball team.

Huyghe T, Calleja-Gonzalez J, Bird S, Alcaraz P Biol Sport. 2024; 41(1):3-15.

PMID: 38188113 PMC: 10765450. DOI: 10.5114/biolsport.2024.125590.


TEST-RETEST RELIABILITY AND RELIABLE CHANGE INDEX OF MOBILE APPLICATION NEUROCOGNITIVE TEST AMONG MIDDLE AND HIGH SCHOOL ATHLETES.

Hashida K, Lee J, Furutani T, Tsushima W, Tamura K J Athl Train. 2023; 2023(preprint).

PMID: 37459377 PMC: 10895400. DOI: 10.4085/1062-6050-0018.23.


References
1.
Brett B, Zuckerman S, Terry D, Solomon G, Iverson G . Normative Data for the Sway Balance System. Clin J Sport Med. 2018; 30(5):458-464. DOI: 10.1097/JSM.0000000000000632. View

2.
Eckner J, Kutcher J, Richardson J . Effect of concussion on clinically measured reaction time in 9 NCAA division I collegiate athletes: a preliminary study. PM R. 2011; 3(3):212-8. PMC: 3643809. DOI: 10.1016/j.pmrj.2010.12.003. View

3.
Gonzalez-Canete F, Casilari E . Consumption Analysis of Smartphone based Fall Detection Systems with Multiple External Wireless Sensors. Sensors (Basel). 2020; 20(3). PMC: 7038232. DOI: 10.3390/s20030622. View

4.
Eckner J, Kutcher J, Richardson J . Pilot evaluation of a novel clinical test of reaction time in national collegiate athletic association division I football players. J Athl Train. 2010; 45(4):327-32. PMC: 2902024. DOI: 10.4085/1062-6050-45.4.327. View

5.
Patterson J, Amick R, Thummar T, Rogers M . Validation of measures from the smartphone sway balance application: a pilot study. Int J Sports Phys Ther. 2014; 9(2):135-9. PMC: 4004118. View