Broken Guidewire Retrieval from the Hip Joint: A Case Report

Overview
Journal Trauma Case Rep
Date 2021 Aug 11
PMID 34377759
Citations 4
Authors
Affiliations
Soon will be listed here.
Abstract

Hardware breakage during orthopaedic surgery especially closed intramedullary nailing is a nightmare for orthopaedic surgeons. During hip fracture surgery a mechanical failure of the guidewire or the reamer poses an additional risk of intrapelvic migration and neurovascular or visceral injury which can lead to devastating complications and litigation. We report a case of removal of the broken guidewire using a cannulated reamer & discectomy forceps and recommend some suggestions for prevention of this catastrophe.

Citing Articles

Intraosseous Retrieval of Broken Guide Wire while Fixing Proximal Femur Fractures - A Report of 2 Cases and Review of Literature.

Samant V, Shaikh A, Desai M, Prabhu R, Sekhrajka R, Somani R J Orthop Case Rep. 2023; 13(11):37-41.

PMID: 38025353 PMC: 10664233. DOI: 10.13107/jocr.2023.v13.i11.3998.


A rare case report: Guiding wire fracture during CT-guided abscess drainage session and subsequent retrieval under fluoroscopy by the endoscopic grasp.

Zhang Y, Lin C, Lu Y, Chuang M Radiol Case Rep. 2023; 19(1):44-47.

PMID: 37886023 PMC: 10598735. DOI: 10.1016/j.radcr.2023.09.079.


Retrieval of broken intra-medullary guide wire in femoral shaft fracture: A case report and surgical technique.

Thakur K, Sharma A, Prasad M, Jindal I Trauma Case Rep. 2023; 46:100865.

PMID: 37347005 PMC: 10279906. DOI: 10.1016/j.tcr.2023.100865.


Association between General Anesthesia and the Occurrence of Cerebrovascular Accidents in Hip Fracture Patients.

Wang H, Gao L J Healthc Eng. 2021; 2021:7271136.

PMID: 34961827 PMC: 8710151. DOI: 10.1155/2021/7271136.

References
1.
Mishra P, Jain P, Aggarwal A, Upadhyay A, Maini L, Gautam V . Intrapelvic protrusion of guide wire during fixation of fracture neck of femur. Injury. 2002; 33(9):839-41. DOI: 10.1016/s0020-1383(02)00172-9. View

2.
Brodell J, Leve A . Disengagement and intrapelvic protrusion of the screw from a sliding screw-plate device. A case report. J Bone Joint Surg Am. 1983; 65(5):697-701. View

3.
Price M, Molloy S, Solan M, Sutton A, Ricketts D . The rate of instrument breakage during orthopaedic procedures. Int Orthop. 2002; 26(3):185-7. PMC: 3620883. DOI: 10.1007/s00264-002-0344-6. View

4.
Sharma H, Chauhan M, Maini L . A technique to remove a broken guide wire transfixing the hip joint. Acta Orthop Belg. 2008; 74(5):683-5. View

5.
Docquier P, Manche E, Autrique J, Geulette B . Complications associated with gamma nailing. A review of 439 cases. Acta Orthop Belg. 2002; 68(3):251-7. View