» Articles » PMID: 34320481

Neural Stimulation and Recording Performance in Human Sensorimotor Cortex over 1500 Days

Overview
Journal J Neural Eng
Date 2021 Jul 28
PMID 34320481
Citations 41
Authors
Affiliations
Soon will be listed here.
Abstract

Intracortical microstimulation (ICMS) in somatosensory cortex can restore sensation to people with spinal cord injury. However, the recording quality from implanted microelectrodes can degrade over time and limitations in stimulation longevity have been considered a potential barrier to the clinical use of ICMS. Our objective was to evaluate recording stability of intracortical electrodes implanted in the motor and somatosensory cortex of one person. The electrodes in motor cortex had platinum tips and were not stimulated, while the electrodes in somatosensory cortex had sputtered iridium oxide film (SIROF) tips and were stimulated. Additionally, we measured how well ICMS was able to evoke sensations over time.. We implanted microelectrode arrays with SIROF tips in the somatosensory cortex (SIROF-sensory) of a human participant with a cervical spinal cord injury. We regularly stimulated these electrodes to evoke tactile sensations on the hand. Here, we quantify the stability of these electrodes in comparison to non-stimulated platinum electrodes implanted in the motor cortex (platinum-motor) over 1500 days with recorded signal quality and electrode impedances. Additionally, we quantify the stability of ICMS-evoked sensations using detection thresholds.. We found that recording quality, as assessed by the number of electrodes with high-amplitude waveforms (>100V peak-to-peak), peak-to-peak voltage, noise, and signal-to-noise ratio, decreased over time on SIROF-sensory and platinum-motor electrodes. However, SIROF-sensory electrodes were more likely to continue to record high-amplitude signals than platinum-motor electrodes. Interestingly, the detection thresholds for stimulus-evoked sensations decreased over time from a median of 31.5A at day 100-10.4A at day 1500, with the largest changes occurring between day 100 and 500.. These results demonstrate that ICMS in human somatosensory cortex can be provided over long periods of time without deleterious effects on recording or stimulation capabilities. In fact, the sensitivity to stimulation improved over time.

Citing Articles

Enhancing neuroprosthesis calibration: the advantage of integrating prior training over exclusive use of new data.

Thomson C, Tully T, Stone E, Morrell C, Scheme E, Warren D J Neural Eng. 2024; 21(6).

PMID: 39569866 PMC: 11605518. DOI: 10.1088/1741-2552/ad94a7.


A click-based electrocorticographic brain-computer interface enables long-term high-performance switch scan spelling.

Candrea D, Shah S, Luo S, Angrick M, Rabbani Q, Coogan C Commun Med (Lond). 2024; 4(1):207.

PMID: 39433597 PMC: 11494178. DOI: 10.1038/s43856-024-00635-3.


Clinical Applications and Future Translation of Somatosensory Neuroprostheses.

Graczyk E, Hutchison B, Valle G, Bjanes D, Gates D, Raspopovic S J Neurosci. 2024; 44(40).

PMID: 39358021 PMC: 11450537. DOI: 10.1523/JNEUROSCI.1237-24.2024.


Quantifying physical degradation alongside recording and stimulation performance of 980 intracortical microelectrodes chronically implanted in three humans for 956-2246 days.

Bjanes D, Kellis S, Nickl R, Baker B, Aflalo T, Bashford L medRxiv. 2024; .

PMID: 39314938 PMC: 11419230. DOI: 10.1101/2024.09.09.24313281.


Enhancing biocompatibility of the brain-machine interface: A review.

Villa J, Cury J, Kessler L, Tan X, Richter C Bioact Mater. 2024; 42:531-549.

PMID: 39308547 PMC: 11416625. DOI: 10.1016/j.bioactmat.2024.08.034.


References
1.
DeYoe E, Lewine J, Doty R . Laminar variation in threshold for detection of electrical excitation of striate cortex by macaques. J Neurophysiol. 2005; 94(5):3443-50. DOI: 10.1152/jn.00407.2005. View

2.
Bullard A, Hutchison B, Lee J, Chestek C, Patil P . Estimating Risk for Future Intracranial, Fully Implanted, Modular Neuroprosthetic Systems: A Systematic Review of Hardware Complications in Clinical Deep Brain Stimulation and Experimental Human Intracortical Arrays. Neuromodulation. 2019; 23(4):411-426. DOI: 10.1111/ner.13069. View

3.
Carmena J, Lebedev M, Crist R, ODoherty J, Santucci D, Dimitrov D . Learning to control a brain-machine interface for reaching and grasping by primates. PLoS Biol. 2003; 1(2):E42. PMC: 261882. DOI: 10.1371/journal.pbio.0000042. View

4.
Kane S, Cogan S, Ehrlich J, Plante T, McCreery D, Troyk P . Electrical performance of penetrating microelectrodes chronically implanted in cat cortex. IEEE Trans Biomed Eng. 2013; 60(8):2153-60. PMC: 7441534. DOI: 10.1109/TBME.2013.2248152. View

5.
Suner S, Fellows M, Vargas-Irwin C, Nakata G, Donoghue J . Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng. 2006; 13(4):524-41. DOI: 10.1109/TNSRE.2005.857687. View