Ability of Carotid Corrected Flow Time to Predict Fluid Responsiveness in Patients Mechanically Ventilated Using Low Tidal Volume After Surgery

Overview
Journal J Clin Med
Specialty General Medicine
Date 2021 Jul 2
PMID 34204523
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Predicting fluid responsiveness in patients under mechanical ventilation with low tidal volume (VT) is challenging. This study evaluated the ability of carotid corrected flow time (FTc) assessed by ultrasound for predicting the fluid responsiveness during low VT ventilation. Patients under postoperative mechanical ventilation and clinically diagnosed with hypovolemia were enrolled. Carotid FTc and pulse pressure variation (PPV) were measured at VT of 6 and 10 mL/kg predicted body weight (PBW). FTc was calculated using both Bazett's (FTcB) and Wodey's (FTcW) formulas. Fluid responsiveness was defined as a ≥15% increase in the stroke volume index assessed by FloTrac/Vigileo monitor after administration of 8 mL/kg of balanced crystalloid. Among 36 patients, 16 (44.4%) were fluid responders. The areas under the receiver operating characteristic curves (AUROCs) for the FTcB at VT of 6 and 10 mL/kg PBW were 0.897 (95% confidence interval [95% CI]: 0.750-0.973) and 0.895 (95% CI: 0.748-0.972), respectively. The AUROCs for the FTcW at VT of 6 and 10 mL/kg PBW were 0.875 (95% CI: 0.722-0.961) and 0.891 (95% CI: 0.744-0.970), respectively. However, PPV at VT of 6 mL/kg PBW (AUROC: 0.714, 95% CI: 0.539-0.852) showed significantly lower accuracy than that of PPV at VT of 10 mL/kg PBW (AUROC: 0.867, 95% CI: 0.712-0.957; = 0.034). Carotid FTc can predict fluid responsiveness better than PPV during low VT ventilation. However, further studies using automated continuous monitoring system are needed before its clinical use.

Citing Articles

A framework for flow time measured by Doppler ultrasound.

Kenny J Ultrasound J. 2025; 17(1):10.

PMID: 39836314 PMC: 11751365. DOI: 10.1186/s13089-025-00414-8.


Predictive value of trendelenburg position and carotid ultrasound for fluid responsiveness in patients on VV-ECMO with acute respiratory distress syndrome in the prone position.

Zhao J, Sun Y, Tang J, Guo K, Zhuge J, Fang H Sci Rep. 2024; 14(1):31808.

PMID: 39738306 PMC: 11685402. DOI: 10.1038/s41598-024-83038-7.


The Reliability of Carotid Artery Doppler Ultrasonography Indices in Predicting Fluid Responsiveness during Surgery for Geriatric Patients: A Prospective, Observational Study.

Bilgili B, Saracoglu A, Saracoglu K, Ratajczyk P, Kararmaz A Healthcare (Basel). 2024; 12(7).

PMID: 38610205 PMC: 11011830. DOI: 10.3390/healthcare12070783.


The correlation between carotid artery Doppler and stroke volume during central blood volume loss and resuscitation.

Kerrebijn I, Atwi S, Elfarnawany M, Eibl A, Eibl J, Taylor J Acute Crit Care. 2024; 39(1):162-168.

PMID: 38476069 PMC: 11002613. DOI: 10.4266/acc.2023.01095.


Carotid blood flow changes following a simulated end-inspiratory occlusion maneuver measured by ultrasound can predict hypotension after the induction of general anesthesia: an observational study.

Jin G, Liu F, Yang Y, Chen J, Wen Q, Wang Y BMC Anesthesiol. 2024; 24(1):13.

PMID: 38172775 PMC: 10763470. DOI: 10.1186/s12871-023-02393-6.


References
1.
Kenny J, Barjaktarevic I, Mackenzie D, Eibl A, Parrotta M, Long B . Diagnostic characteristics of 11 formulae for calculating corrected flow time as measured by a wearable Doppler patch. Intensive Care Med Exp. 2020; 8(1):54. PMC: 7498524. DOI: 10.1186/s40635-020-00339-7. View

2.
Brower R, Matthay M, Morris A, Schoenfeld D, Thompson B, Wheeler A . Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med. 2000; 342(18):1301-8. DOI: 10.1056/NEJM200005043421801. View

3.
Jozwiak M, Monnet X, Teboul J . Prediction of fluid responsiveness in ventilated patients. Ann Transl Med. 2018; 6(18):352. PMC: 6186547. DOI: 10.21037/atm.2018.05.03. View

4.
Shokoohi H, Berry G, Shahkolahi M, King J, King J, Salimian M . The diagnostic utility of sonographic carotid flow time in determining volume responsiveness. J Crit Care. 2016; 38:231-235. DOI: 10.1016/j.jcrc.2016.10.025. View

5.
Krige A, Bland M, Fanshawe T . Fluid responsiveness prediction using Vigileo FloTrac measured cardiac output changes during passive leg raise test. J Intensive Care. 2016; 4:63. PMC: 5052799. DOI: 10.1186/s40560-016-0188-6. View