On the Down-sampling of Diffusion MRI Data Along the Angular Dimension
Overview
Affiliations
Background: It has been established that the diffusion gradient directions in diffusion MRI should be uniformly distributed in 3D spherical space, so that orientation-dependent diffusion properties (e.g., fractional anisotropy or FA) can be properly quantified. Sometimes the acquired data need to be down-sampled along the angular dimension before computing diffusion properties (e.g., to exclude data points corrupted by motion artifact; to harmonize data obtained with different protocols). It is important to quantitatively assess the impact of data down-sampling on measurement of diffusion properties.
Materials And Methods: Here we report 1) a numerical procedure for down-sampling diffusion MRI (e.g., for data harmonization), and 2) a spatial uniformity index of diffusion directions, aiming to predict the quality of the chosen down-sampling schemes (e.g., from data harmonization; or rejection of motion corrupted data points). We quantitatively evaluated human diffusion MRI data, which were down-sampled from 64 or 60 diffusion gradient directions to 30 directions, in terms of their 1) FA value accuracy (using fully-sampled data as the ground truth), 2) FA fitting residuals, and 3) spatial uniformity indices.
Results: Our experimental data show that the proposed spatial uniformity index is correlated with errors in FA obtained from down-sampled diffusion MRI data. The FA fitting residuals that are typically used to assess diffusion MRI quality are not correlated with either FA errors or spatial uniformity index.
Conclusions: These results suggest that the spatial uniformity index could be more valuable in assessing quality of down-sampled diffusion MRI data, as compared with FA fitting residual measures. We expect that our implemented software procedure should prove valuable for 1) guiding data harmonization for multi-site diffusion MRI studies, and 2) assessing the impact of rejecting motion corrupted data points on the accuracy of diffusion measures.
Cocaine Use Prediction With Tensor-Based Machine Learning on Multimodal MRI Connectome Data.
Zhang A, Bell R, An C, Tang R, Hall S, Chan C Neural Comput. 2023; 36(1):107-127.
PMID: 38052079 PMC: 11075092. DOI: 10.1162/neco_a_01623.
Li X, Towe S, Bell R, Jiang R, Hall S, Calhoun V IEEE J Biomed Health Inform. 2023; PP.
PMID: 37022271 PMC: 10387132. DOI: 10.1109/JBHI.2023.3240508.
Strengthened and posterior-shifted structural rich-club organization in people who use cocaine.
Hall S, Bell R, Gadde S, Towe S, Nadeem M, McCann P Drug Alcohol Depend. 2022; 235:109436.
PMID: 35413558 PMC: 9948276. DOI: 10.1016/j.drugalcdep.2022.109436.