» Articles » PMID: 11969328

A Model-based Method for Retrospective Correction of Geometric Distortions in Diffusion-weighted EPI

Overview
Journal Neuroimage
Specialty Radiology
Date 2002 Apr 24
PMID 11969328
Citations 123
Authors
Affiliations
Soon will be listed here.
Abstract

The self-diffusion tensor may be calculated from several echo-planar image acquisitions preceded by different diffusion gradients. Unfortunately, these diffusion gradients cause geometric distortion that must be corrected before estimation of the tensor. In the present paper we suggest and implement a method for retrospective correction of these distortions firmly based on a physical model for the diffusion-weighted images. This method simultaneously estimates subject movement and distortion parameters by finding the set of parameters that minimizes residual error when fitting data to the diffusion tensor model. We show how this notion can be formalized as a quadratic form thereby facilitating the implementation of a rapid algorithm. In addition, we suggest models for how distortions vary with slice position and gradient direction that allow us to substantially reduce the dimensionality of the parameter space. Our results indicate that we are able to estimate both eddy current-induced distortion and subject movement directly from the data without need of any additional measurements.

Citing Articles

CSF levels of brain-derived proteins correlate with brain ventricular volume in cognitively healthy 70-year-olds.

Bergstrom S, Mravinacova S, Lindberg O, Zettergren A, Westman E, Wahlund L Clin Proteomics. 2024; 21(1):65.

PMID: 39668376 PMC: 11636040. DOI: 10.1186/s12014-024-09517-1.


Evaluating Reproducibility of the ADC and Distortion in Diffusion-weighted Imaging (DWI) with Reverse Encoding Distortion Correction (RDC).

Numamoto H, Fujimoto K, Miyake K, Fushimi Y, Okuchi S, Imai R Magn Reson Med Sci. 2023; 24(1):66-77.

PMID: 37952942 PMC: 11733504. DOI: 10.2463/mrms.mp.2023-0102.


Improved dynamic distortion correction for fMRI using single-echo EPI and a readout-reversed first image (REFILL).

Robinson S, Bachrata B, Eckstein K, Bollmann S, Bollmann S, Hodono S Hum Brain Mapp. 2023; 44(15):5095-5112.

PMID: 37548414 PMC: 10502646. DOI: 10.1002/hbm.26440.


DENOISING DIFFUSION MRI: CONSIDERATIONS AND IMPLICATIONS FOR ANALYSIS.

Manzano-Patron J, Moeller S, Andersson J, Ugurbil K, Yacoub E, Sotiropoulos S bioRxiv. 2023; .

PMID: 37546835 PMC: 10402048. DOI: 10.1101/2023.07.24.550348.


Simultaneous multislice EPI prospective motion correction by real-time receiver phase correction and coil sensitivity map interpolation.

Li B, Li N, Wang Z, Balan R, Ernst T Magn Reson Med. 2023; 90(5):1932-1948.

PMID: 37448116 PMC: 10795703. DOI: 10.1002/mrm.29789.