» Articles » PMID: 34063596

Development and Evaluation of a Quantitative Fluorescent Lateral Flow Immunoassay for Cystatin-C, a Renal Dysfunction Biomarker

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2021 Jun 2
PMID 34063596
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

The diagnosis, prognosis, and control of chronic kidney disease rely on an understanding of the glomerular filtration rate (GFR). The renal clearance of the cystatin-C is closely associated with the GFR. Cystatin-C is a more suitable GFR marker than the commonly used creatinine. General techniques for cystatin-C calculation, such as particle-enhanced turbidimetric and nephelometric assay, are time-consuming and tedious. Here, we propose a rapid, quantitative immunoassay for the detection of cystatin-C. A fluorescence-based lateral-flow kit was developed in a sandwich format by using a monoclonal antibody. A Linear calibration was obtained over the clinical diagnostic range of 0.023-32 µg/mL and the limit of detection (LOD) was 0.023 µg/mL and the limit of quantification (LOQ) was 0.029 µg/mL. Average recoveries from spiked urine samples ranged from 96-100% and the coefficient of variation was less than 4% for both intra and inter-day assays with excellent repeatability. With the comparison with an ELISA kit, the developed kit is highly sensitive, performs well over the detection range, provides repeatable results in a short time, and can easily be used at point-of-care (POC), making it an ideal candidate for rapid testing in early detection, community screening for renal function disorders.

Citing Articles

Emerging trends in the cystatin C sensing technologies: towards better chronic kidney disease management.

Raveendran J, Gangadharan D, Bayry J, Rasheed P RSC Adv. 2025; 15(7):4926-4944.

PMID: 39957820 PMC: 11826153. DOI: 10.1039/d4ra07197b.


The development of lateral flow devices for urinary biomarkers to assess kidney health.

D Souza S, Obeid W, Hernandez J, Hu D, Wen Y, Moledina D Sci Rep. 2024; 14(1):8516.

PMID: 38609491 PMC: 11014899. DOI: 10.1038/s41598-024-59104-5.


The Quantitative Detection of Cystatin-C in Patient Samples Using a Colorimetric Lateral Flow Immunoassay.

Bikkarolla S, Venkatesan K, Revathy Y, Parameswaran S, Krishnakumar S, Dendukuri D Biosensors (Basel). 2024; 14(1).

PMID: 38248407 PMC: 10813198. DOI: 10.3390/bios14010030.


Controlling Fluorescent Readout in Paper-based Analytical Devices.

Luongo A, von Stockert A, Scherag F, Brandstetter T, Biesalski M, Ruhe J ACS Biomater Sci Eng. 2023; 9(11):6379-6389.

PMID: 37875260 PMC: 10649804. DOI: 10.1021/acsbiomaterials.3c00736.


Bio-conjugated nanoarchitectonics with dual-labeled nanoparticles for a colorimetric and fluorescent dual-mode serological lateral flow immunoassay sensor in detection of SARS-CoV-2 in clinical samples.

Kim S, Lee J, Jeon M, Kim S, Hwang S, Hong M RSC Adv. 2023; 13(39):27225-27232.

PMID: 37701275 PMC: 10494995. DOI: 10.1039/d3ra04373h.


References
1.
Neild G . Life expectancy with chronic kidney disease: an educational review. Pediatr Nephrol. 2016; 32(2):243-248. PMC: 5203814. DOI: 10.1007/s00467-016-3383-8. View

2.
Jeyachandran Y, Mielczarski J, Mielczarski E, Rai B . Efficiency of blocking of non-specific interaction of different proteins by BSA adsorbed on hydrophobic and hydrophilic surfaces. J Colloid Interface Sci. 2009; 341(1):136-42. DOI: 10.1016/j.jcis.2009.09.007. View

3.
Finney H, Newman D, Price C . Adult reference ranges for serum cystatin C, creatinine and predicted creatinine clearance. Ann Clin Biochem. 2000; 37 ( Pt 1):49-59. DOI: 10.1258/0004563001901524. View

4.
Higgins C, Neybold P, Holdridge M, Barnes C, Dong Y, Reeve M . Performance of the 4Kscore Test in Plasma and Serum and Stability of the Component Analytes in Clinical Samples. J Appl Lab Med. 2021; 3(2):185-199. DOI: 10.1373/jalm.2017.024612. View

5.
Tao J, Zhao P, Zeng Q . The determination of cystatin C in serum based on label-free and near-infrared light emitted PbS@BSA QDs. J Mater Chem B. 2020; 4(24):4258-4262. DOI: 10.1039/c6tb00080k. View