» Articles » PMID: 34049514

Quantitative Visual Tests in Primary Open-angle Glaucoma Patients According to Three Different Lights with Different Color-rendering Index

Overview
Journal BMC Ophthalmol
Publisher Biomed Central
Specialty Ophthalmology
Date 2021 May 29
PMID 34049514
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare quantitative visual tests, such as visual acuity, contrast sensitivity, and color vision tests in patients with primary open-angle glaucoma (POAG) patients according to three different light systems with different color-rendering index (CRI).

Methods: This was a cross-sectional study of 36 eyes in 36 patients with POAG. Three different light systems consisting of a 3-band fluorescent lamp (CRI 80), a white LED (CRI 75), and a quantum dot LED (CRI > 95) were used. All lights had the same illuminance of 230 lx to exclude illuminance effects. The visual testing included best-corrected visual acuity (BCVA) using an ETDRS chart, a CSV-1000E contrast test, and a color test performed by the Farnsworth Munsell 100-hue test.

Results: There was no significant difference in BCVA (p = 0.86). There were no significant differences in the detail contrast tests according to the three light systems (p = 0.95, p = 0.94, p = 0.94, respectively, p = 0.64). There was significant difference between the three light systems in color test (p = 0.042). The color test scores with a quantum dot LED were significantly lower than those of the white LED and 3-band fluorescent lamp (p = 0.03 and 0.047, respectively).

Conclusions: POAG patients did not show significant differences in visual acuity scores and contrast test scores, expressed as black and white symbols, according to the different light systems. However, POAG patients tested under a quantum dot LED (CRI > 95) could distinguish color differences better than in the other light systems.

References
1.
Gunduz K, Arden G, Perry S, WEINSTEIN G, Hitchings R . Color vision defects in ocular hypertension and glaucoma. Quantification with a computer-driven color television system. Arch Ophthalmol. 1988; 106(7):929-35. DOI: 10.1001/archopht.1988.01060140075028. View

2.
Yoon H, Oh J, Lee S, Park J, Do Y . Circadian-tunable Perovskite Quantum Dot-based Down-Converted Multi-Package White LED with a Color Fidelity Index over 90. Sci Rep. 2017; 7(1):2808. PMC: 5459832. DOI: 10.1038/s41598-017-03063-7. View

3.
Park C, Kim D, Lee C . Near and Distance Stereoacuity in Patients With Primary Open-angle Glaucoma. J Glaucoma. 2018; 27(6):537-542. DOI: 10.1097/IJG.0000000000000963. View

4.
Sheedy J, Bailey I, Raasch T . Visual acuity and chart luminance. Am J Optom Physiol Opt. 1984; 61(9):595-600. DOI: 10.1097/00006324-198409000-00010. View

5.
Alqudah A, Mansberger S, Gardiner S, Demirel S . Vision-related Quality of Life in Glaucoma Suspect or Early Glaucoma Patients. J Glaucoma. 2016; 25(8):629-33. PMC: 4975427. DOI: 10.1097/IJG.0000000000000445. View