Test-retest Reliability of the CSV-1000 Contrast Test and Its Relationship to Glaucoma Therapy

Overview
Specialty Ophthalmology
Date 1994 Aug 1
PMID 8056510
Citations 61
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To determine the relationship between changes in contrast sensitivity, if any, after glaucoma therapy and the test-retest reliability of the CSV-1000 contrast sensitivity test.

Methods: Patients with primary open angle glaucoma (N = 16) were retrospectively evaluated to determine changes in visual function, as measured by contrast sensitivity, after beta-blocker therapy. A control group (N = 24) of normally sighted patients was tested and retested on contrast sensitivity. For the control group, the coefficients of repeatability (95% confidence interval for test-retest variability [COR]) were calculated for each spatial frequency. The CORs were compared to the changes in vision found after therapy in the patients with glaucoma.

Results: The group with glaucoma showed a significant improvement (P < .01) in contrast sensitivity at all spatial frequencies. The test-retest variance for normals, as measured by the COR, was smaller than the mean differences in contrast sensitivity before and after therapy at all spatial frequencies, expect 18 cyc/deg.

Conclusions: Visual function in patients with glaucoma, as measured by contrast sensitivity, does improve after beta-blocker therapy. Further, the CSV-1000 is a clinically reliable tool for monitoring these changes.

Citing Articles

Clinical outcomes of a hydrophobic trifocal diffractive intraocular lens: a literature review.

Ristvedt D, Bosc C, Thompson V Front Med (Lausanne). 2025; 12:1533161.

PMID: 39911861 PMC: 11794266. DOI: 10.3389/fmed.2025.1533161.


Motion onset VEPs can see through the blur.

Kordek D, Young L, Voda P, Kremlacek J Sci Rep. 2024; 14(1):21296.

PMID: 39266612 PMC: 11393312. DOI: 10.1038/s41598-024-72483-z.


Validation of a New Test for Measuring the Contrast Sensitivity Function (Optopad-CSF) at Near Vision.

de Fez D, Garcia C, Luque-Cobija M, Mena-Guevara K, Dauden P, Pinero D Diagnostics (Basel). 2024; 14(13).

PMID: 39001266 PMC: 11241259. DOI: 10.3390/diagnostics14131377.


Test-retest repeatability and agreement of the quantitative contrast sensitivity function test: towards the validation of a new clinical endpoint.

Finn M, Vingopoulos F, Zhao Y, Zhou P, Bannerman A, Romano F Graefes Arch Clin Exp Ophthalmol. 2023; 262(3):813-822.

PMID: 37955702 DOI: 10.1007/s00417-023-06291-y.


Evaluation of extended depth-of-focus hydrophobic intraocular lens with an optic concept based on combination of high-order aberrations.

Stodulka P, Pracharova Z Ther Adv Ophthalmol. 2023; 15:25158414231200108.

PMID: 37799815 PMC: 10548805. DOI: 10.1177/25158414231200108.