» Articles » PMID: 34043907

Ophthalmic Sensors and Drug Delivery

Overview
Journal ACS Sens
Specialty Biotechnology
Date 2021 May 27
PMID 34043907
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Advances in multifunctional materials and technologies have allowed contact lenses to serve as wearable devices for continuous monitoring of physiological parameters and delivering drugs for ocular diseases. Since the tear fluids comprise a library of biomarkers, direct measurement of different parameters such as concentration of glucose, urea, proteins, nitrite, and chloride ions, intraocular pressure (IOP), corneal temperature, and pH can be carried out non-invasively using contact lens sensors. Microfluidic contact lens sensor based colorimetric sensing and liquid control mechanisms enable the wearers to perform self-examinations at home using smartphones. Furthermore, drug-laden contact lenses have emerged as delivery platforms using a low dosage of drugs with extended residence time and increased ocular bioavailability. This review provides an overview of contact lenses for ocular diagnostics and drug delivery applications. The designs, working principles, and sensing mechanisms of sensors and drug delivery systems are reviewed. The potential applications of contact lenses in point-of-care diagnostics and personalized medicine, along with the significance of integrating multiplexed sensing units together with drug delivery systems, have also been discussed.

Citing Articles

Fish Fin-Derived Non-Invasive Flexible Bioinspired Contact Lens for Continuous Ophthalmic Drug Delivery.

Li X, Li H, Wang Z, Wang X, Zhang J, Bin F Adv Sci (Weinh). 2024; 12(6):e2412630.

PMID: 39686625 PMC: 11809385. DOI: 10.1002/advs.202412630.


Tear-Based Ocular Wearable Biosensors for Human Health Monitoring.

Rajan A, Vishnu J, Shankar B Biosensors (Basel). 2024; 14(10).

PMID: 39451696 PMC: 11506517. DOI: 10.3390/bios14100483.


Approaches of wearable and implantable biosensor towards of developing in precision medicine.

Ghazizadeh E, Naseri Z, Deigner H, Rahimi H, Altintas Z Front Med (Lausanne). 2024; 11:1390634.

PMID: 39091290 PMC: 11293309. DOI: 10.3389/fmed.2024.1390634.


Drug-Modified Contact Lenses-Properties, Release Kinetics, and Stability of Active Substances with Particular Emphasis on Cyclosporine A: A Review.

Rykowska I, Michalkiewicz O, Nowak I, Nowak R Molecules. 2024; 29(11).

PMID: 38893485 PMC: 11173495. DOI: 10.3390/molecules29112609.


Corneal biomechanics and diagnostics: a review.

Komninou M, Seiler T, Enzmann V Int Ophthalmol. 2024; 44(1):132.

PMID: 38478103 PMC: 10937779. DOI: 10.1007/s10792-024-03057-1.


References
1.
Olansky L, Kennedy L . Finger-stick glucose monitoring: issues of accuracy and specificity. Diabetes Care. 2010; 33(4):948-9. PMC: 2845057. DOI: 10.2337/dc10-0077. View

2.
Patel N, Nakrani H, Raval M, Sheth N . Development of loteprednol etabonate-loaded cationic nanoemulsified in-situ ophthalmic gel for sustained delivery and enhanced ocular bioavailability. Drug Deliv. 2016; 23(9):3712-3723. DOI: 10.1080/10717544.2016.1223225. View

3.
DiCesare N, Lakowicz J . Chalcone-analogue fluorescent prfobes for saccharides signaling using the boronic acid group. Tetrahedron Lett. 2021; 43(14):2615-2618. PMC: 8022852. DOI: 10.1016/s0040-4039(02)00312-x. View

4.
Tan H, Chu C, Payne K, Marra K . Injectable in situ forming biodegradable chitosan-hyaluronic acid based hydrogels for cartilage tissue engineering. Biomaterials. 2009; 30(13):2499-506. PMC: 2676686. DOI: 10.1016/j.biomaterials.2008.12.080. View

5.
Ruan J, Chen C, Shen J, Zhao X, Qian S, Zhu Z . A Gelated Colloidal Crystal Attached Lens for Noninvasive Continuous Monitoring of Tear Glucose. Polymers (Basel). 2019; 9(4). PMC: 6432312. DOI: 10.3390/polym9040125. View