Voltammetric-based Immunosensor for the Detection of SARS-CoV-2 Nucleocapsid Antigen
Overview
Chemistry
Affiliations
Since the COVID-19 disease caused by the novel severe acute respiratory syndrome coronavirus 2 (SARS- CoV-2) was declared a pandemic, it has spread rapidly, causing one of the most serious outbreaks in the last century. Reliable and rapid diagnostic tests for COVID-19 are crucial to control and manage the outbreak. Here, a label-free square wave voltammetry-based biosensing platform for the detection of SARS-CoV-2 in nasopharyngeal samples is reported. The sensor was constructed on screen-printed carbon electrodes coated with gold nanoparticles. The electrodes were functionalized using 11-mercaptoundecanoic acid (MUA) which was used for the immobilization of an antibody against SARS-CoV-2 nucleocapsid protein (N protein). The binding of the immunosensor with the N protein caused a change in the electrochemical signal. The detection was realised by measuring the change in reduction peak current of a redox couple using square wave voltammetry at 0.04 V versus Ag ref. electrode on the immunosensor upon binding with the N protein. The electrochemical immunosensor showed high sensitivity with a linear range from 1.0 pg.mL to 100 ng.mL and a limit of detection of 0.4 pg.mL for the N protein in PBS buffer pH 7.4. Moreover, the immunosensor did not exhibit significant response with other viruses such as HCoV, MERS-CoV, Flu A and Flu B, indicating the high selectivity of the sensor for SARS-CoV-2. However, cross reactivity of the biosensor with SARS-CoV is indicated, which gives ability of the sensor to detect both SARS-CoV and SARS-CoV-2. The biosensor was successfully applied to detect the SARS-CoV-2 virus in clinical samples showing good correlation between the biosensor response and the RT-PCR cycle threshold values. We believe that the capability of miniaturization, low-cost and fast response of the proposed label-free electrochemical immunosensor will facilitate the point-of-care diagnosis of COVID 19 and help prevent further spread of infection.
Pandiyaraj K, Elkaffas R, Mohideen M, Eissa S Sci Rep. 2024; 14(1):17172.
PMID: 39060466 PMC: 11282068. DOI: 10.1038/s41598-024-68231-y.
Utilizing COVID-19 as a Model for Diagnostics Using an Electrochemical Sensor.
Gevaerd A, Carneiro E, Gogola J, Nicollete D, Santiago E, Riedi H Sensors (Basel). 2024; 24(12).
PMID: 38931556 PMC: 11207896. DOI: 10.3390/s24123772.
Kim Y, Min J Nano Converg. 2024; 11(1):3.
PMID: 38206526 PMC: 10784265. DOI: 10.1186/s40580-023-00410-5.
du Plooy J, Jahed N, Iwuoha E, Pokpas K R Soc Open Sci. 2023; 10(11):230940.
PMID: 38034121 PMC: 10685120. DOI: 10.1098/rsos.230940.
Batra J, Chi T, Huang M, Zhu D, Chen Z, Lee D Biosensors (Basel). 2023; 13(9).
PMID: 37754095 PMC: 10527467. DOI: 10.3390/bios13090861.