» Articles » PMID: 34017436

The Effects of on Hemodynamics, Oxygen Saturation, Peak Airway Pressure and Adverse Events During Anesthesia for Thyroid Surgery: Tracheal Intubation Vs. ProSeal Laryngeal Mask Airway

Overview
Journal Am J Transl Res
Specialty General Medicine
Date 2021 May 21
PMID 34017436
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To investigate the effect of tracheal intubation and ProSeal laryngeal mask airway (PLMA) on hemodynamics, oxygen saturation, peak airway pressure and adverse events during anesthesia for thyroid surgery.

Methods: 65 patients who underwent luminal thyroid surgery under general anesthesia were enrolled as the study subjects, and were divided into control group (30 patients, tracheal intubation) and experimental group (35 patients, PLMA) using random number table. The time to establishment of artificial airway and success rate, hemodynamics, oxygen saturation, peak airway pressure and adverse effects were observed in the two groups.

Results: The SBP, DBP, and HR levels of patients in the experimental group were significantly lower than those of control group (P < 0.05), and there were no significant changes in SBP, DBP, and HR levels during the insertion and removal of the laryngeal mask, and the patients were hemodynamically stable. SpO and Ppeak values remained stable at 5 min, 30 min, and 60 min after the start and the end of surgery in both groups, and showed no significant difference between the two groups (P > 0.05). A surgical airway was quickly established in both groups, and the time to airway establishment was shorter in the experimental group than in the control group. The incidence of adverse reactions during extubation was lower in the experimental group than in the control group, and the incidence of hoarseness, choking and cough differed significantly between the two groups (P < 0.05), and the adverse reactions in both groups were relieved or disappeared 24 h after the operation.

Conclusion: With LMPA, patients are more hemodynamically stable during insertion and removal of the mask, have a lower incidence of adverse events, and experience less throat irritation, with safety.

Citing Articles

Efficacy of laryngeal mask airway against postoperative pharyngolaryngeal complications following thyroid surgery: a systematic review and meta-analysis of randomized controlled studies.

Hung K, Wu S, Hsu C, Ko C, Chen J, Huang P Sci Rep. 2022; 12(1):18210.

PMID: 36307459 PMC: 9616911. DOI: 10.1038/s41598-022-21989-5.


Efficacy of propofol for the prevention of emergence agitation after sevoflurane anaesthesia in children: A meta-analysis.

Xiao Y, Jin X, Zhang Y, Huang T, Zhou L, Gao J Front Surg. 2022; 9:1031010.

PMID: 36263091 PMC: 9574203. DOI: 10.3389/fsurg.2022.1031010.

References
1.
Shah K . ProSeal laryngeal mask airway as an alternative to standard endotracheal tube in securing upper airway in the patients undergoing beating-heart coronary artery bypass grafting. Ann Card Anaesth. 2017; 20(1):61-66. PMC: 5290698. DOI: 10.4103/0971-9784.197838. View

2.
Gong Y, Xu X, Wang J, Che L, Wang W, Yi J . Laryngeal mask airway reduces incidence of post-operative sore throat after thyroid surgery compared with endotracheal tube: a single-blinded randomized controlled trial. BMC Anesthesiol. 2020; 20(1):16. PMC: 6961403. DOI: 10.1186/s12871-020-0932-2. View

3.
Chen W, Li H, Sun K, Zheng R, Zhang S, Zeng H . [Report of Cancer Incidence and Mortality in China, 2014]. Zhonghua Zhong Liu Za Zhi. 2018; 40(1):5-13. DOI: 10.3760/cma.j.issn.0253-3766.2018.01.002. View

4.
Shin H, Yoo H, Bae G, Chang J, Park M, You H . Comparison of oropharyngeal leak pressure and clinical performance of LMA ProSeal™ and i-gel® in adults: Meta-analysis and systematic review. J Int Med Res. 2016; 44(3):405-18. PMC: 5536706. DOI: 10.1177/0300060515607386. View

5.
Uesugi T, Tanimoto M . [Evaluation of 13 cases of upper airway obstruction caused by laryngeal mask ProSeal, improved by other types of laryngeal mask airway]. Masui. 2012; 61(6):588-94. View