Strip-based Digital Image Registration for Distortion Minimization and Robust Eye Motion Measurement from Scanned Ophthalmic Imaging Systems

Overview
Specialty Radiology
Date 2021 May 17
PMID 33996234
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Retinal image-based eye motion measurement from scanned ophthalmic imaging systems, such as scanning laser ophthalmoscopy, has allowed for precise real-time eye tracking at sub-micron resolution. However, the constraints of real-time tracking result in a high error tolerance that is detrimental for some eye motion measurement and imaging applications. We show here that eye motion can be extracted from image sequences when these constraints are lifted, and all data is available at the time of registration. Our approach identifies and discards distorted frames, detects coarse motion to generate a synthetic reference frame and then uses it for fine scale motion tracking with improved sensitivity over a larger area. We demonstrate its application here to tracking scanning laser ophthalmoscopy (TSLO) and adaptive optics scanning light ophthalmoscopy (AOSLO), and show that it can successfully capture most of the eye motion across each image sequence, leaving only between 0.1-3.4% of non-blink frames untracked, while simultaneously minimizing image distortions induced from eye motion. These improvements will facilitate precise measurement of fixational eye movements (FEMs) in TSLO and longitudinal tracking of individual cells in AOSLO.

Citing Articles

The fundamentals of eye tracking part 4: Tools for conducting an eye tracking study.

Niehorster D, Nystrom M, Hessels R, Andersson R, Benjamins J, Hansen D Behav Res Methods. 2025; 57(1):46.

PMID: 39762687 PMC: 11703944. DOI: 10.3758/s13428-024-02529-7.


Multi-spectral autofluorescence variability of the individual retinal pigmented epithelial cells in healthy aging eyes.

Lee D, Zhang M, Snyder V, Rossi E Sci Rep. 2024; 14(1):30012.

PMID: 39622926 PMC: 11612473. DOI: 10.1038/s41598-024-81433-8.


High refresh rate display for natural monocular viewing in AOSLO psychophysics experiments.

Moon B, Linebach G, Yang A, Jenks S, Rucci M, Poletti M Opt Express. 2024; 32(18):31142-31161.

PMID: 39573257 PMC: 11595291. DOI: 10.1364/OE.529199.


Improved tracking of corneal immune cell dynamics using confocal microscopy.

Bedggood P, Wu M, Zhang X, Rajan R, Wu C, Karunaratne S Biomed Opt Express. 2024; 15(11):6277-6298.

PMID: 39553868 PMC: 11563322. DOI: 10.1364/BOE.536553.


Are the Hypo-Reflective Clumps Associated With Age-Related Macular Degeneration in Adaptive Optics Ophthalmoscopy Autofluorescent?.

Borella Y, Danielsen N, Markle E, Snyder V, Lee D, Zhang M Invest Ophthalmol Vis Sci. 2024; 65(10):28.

PMID: 39167400 PMC: 11343010. DOI: 10.1167/iovs.65.10.28.


References
1.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

2.
Rucci M, Poletti M . Control and Functions of Fixational Eye Movements. Annu Rev Vis Sci. 2016; 1:499-518. PMC: 5082990. DOI: 10.1146/annurev-vision-082114-035742. View

3.
Bowers N, Boehm A, Roorda A . The effects of fixational tremor on the retinal image. J Vis. 2019; 19(11):8. PMC: 6750810. DOI: 10.1167/19.11.8. View

4.
Sincich L, Zhang Y, Tiruveedhula P, Horton J, Roorda A . Resolving single cone inputs to visual receptive fields. Nat Neurosci. 2009; 12(8):967-9. PMC: 2735134. DOI: 10.1038/nn.2352. View

5.
Mujat M, Ferguson R, Patel A, Iftimia N, Lue N, Hammer D . High resolution multimodal clinical ophthalmic imaging system. Opt Express. 2010; 18(11):11607-21. PMC: 2958093. DOI: 10.1364/OE.18.011607. View