» Articles » PMID: 33980910

Dilute Pilocarpine Test for Diagnosis of Adie's Tonic Pupil

Overview
Journal Sci Rep
Specialty Science
Date 2021 May 13
PMID 33980910
Citations 1
Authors
Affiliations
Soon will be listed here.
Abstract

We have compared the diagnostic ability of different concentrations of 0.125% and 0.0625% dilute pilocarpine for detecting denervation supersensitivity in unilateral Adie's tonic pupil. This retrospective, observational, case-control study involved 117 subjects, consisting of 56 patients with unilateral Adie's tonic pupil and 61 controls with other causes of unilateral dilated pupils. Subjects underwent the dilute pilocarpine test with one of the two concentrations, 0.125% or 0.0625%. Pupillary light reflex was recorded with a dynamic pupillometer at baseline and at 30-40 min after instilling one of the two concentrations of dilute pilocarpine. Diagnostic accuracy of two different concentrations of the dilute pilocarpine test, 0.125% group versus 0.0625% group, were compared by area under the receiver operating characteristic curve (AUC). Diagnostic ability of the dilute pilocarpine test for detecting denervation supersensitivity in unilateral Adie's tonic pupil was significantly better in the 0.0625% group than in the 0.125% group (AUC = 0.954 vs. 0.840, respectively, P = 0.047). In the 0.0625% group, the change in maximal pupil diameter of ≥ 0.5 mm after topical pilocarpine instillation showed 100% sensitivity and 82.8% specificity for detecting Adie's tonic pupil. This study confirmed that pupillary constriction with 0.0625% pilocarpine is better than 0.125% pilocarpine for detecting denervation supersensitivity in Adie's tonic pupil. Digital pupillometry is a reliable method for assessing denervation supersensitivity in Adie's tonic pupil.

Citing Articles

Examination of the autonomic nervous system at the bedside.

Panigrahi B, Srivastava A, Garg D, Jaryal A Acta Neurol Belg. 2024; .

PMID: 39636352 DOI: 10.1007/s13760-024-02654-2.

References
1.
Dienes Z . Bayesian Versus Orthodox Statistics: Which Side Are You On?. Perspect Psychol Sci. 2015; 6(3):274-90. DOI: 10.1177/1745691611406920. View

2.
Cohen L, Rosenberg M, Tanna A, Volpe N . A Novel Computerized Portable Pupillometer Detects and Quantifies Relative Afferent Pupillary Defects. Curr Eye Res. 2015; 40(11):1120-7. DOI: 10.3109/02713683.2014.980007. View

3.
Jacobson D, Olson K . Influence of pupil size, anisocoria, and ambient light on pilocarpine miosis. Implications for supersensitivity testing. Ophthalmology. 1993; 100(2):275-80. DOI: 10.1016/s0161-6420(93)31659-3. View

4.
Thiagarajan P, Ciuffreda K . Pupillary responses to light in chronic non-blast-induced mTBI. Brain Inj. 2015; 29(12):1420-5. DOI: 10.3109/02699052.2015.1045029. View

5.
Thompson H . Adie's syndrome: some new observations. Trans Am Ophthalmol Soc. 1977; 75:587-626. PMC: 1311565. View