» Articles » PMID: 33897192

Comparative Study of Outcomes Between Locking Plates and Three-dimensional Plates in Mandibular Fractures

Overview
Date 2021 Apr 26
PMID 33897192
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The objective was to compare the efficiency and assess postoperative complications of 2.00 mm unicortical locking plates and three-dimensional (3D) plates in surgical correction of uncomplicated mandibular fracture.

Materials And Methods: A prospective cohort study of twenty patients of uncomplicated mandibular fractures, who were operated either by noncompression unicortical 2-mm locking mini-plate or by noncompression unicortical 2-mm 3D mini-plate, were enrolled and followed up for the study outcomes such as operative time, postoperative infection, and postoperative occlusion.

Results: Majority of the patients (90%) were male who had road traffic accident. In 80% of cases, mandibular fracture site was parasymphysis. The mean operating time for 3D plates (43.20 min) was significantly lower than that for locking plates (54.82 min), < 0.001. All cases operated by 3D plates compared to 60% by locking mini-plates did not need intermaxillary fixation, = 0.025. The 80% of cases operated by 3D plates did not require postoperative occlusion correction compared to 30% in another group, = 0.01. For other parameters such as postoperative sensory disturbance, postoperative infection, incidence tooth damage, vertical displacement of mandible, feeling of plate after platting, and chewing efficiency after 1 week, there were no statistical significant differences between the two groups.

Conclusions: The outcome of 2.0mm 3D mini-plate is better in terms of operating time required, post-operative need of intermaxillary fixation and occlusal correction. While the outcome is similar to the use of non-compression unicortical 2.00mm locking miniplate in parameters like infection rate and incidence of tooth damage etc.

Citing Articles

Complications following miniplate insertion in maxillofacial fractures: a systematic review.

Sejati B, Kusumaatmaja A, Widiastuti M, Haniastuti T F1000Res. 2025; 13:1507.

PMID: 40028448 PMC: 11869201. DOI: 10.12688/f1000research.159017.2.


Pre-adjusted Three-Dimensional Plate Employing Printing versus Conventional Plate in the Management of Mandibular Fractures - A Comparative Study.

Kende P, Sarda A, Landge J, Wadewale M, Kri M, Ranganath S Ann Maxillofac Surg. 2024; 13(2):163-166.

PMID: 38405567 PMC: 10883210. DOI: 10.4103/ams.ams_197_22.


Efficacy of Three-dimensional Locking Miniplates versus Three-dimensional Standard Miniplates in the Management of Mandibular Fractures - A Prospective Clinical Study.

Fathima A, Giraddi G, Mamthashri V, Punjabi R, Younus A Ann Maxillofac Surg. 2024; 13(2):149-153.

PMID: 38405556 PMC: 10883216. DOI: 10.4103/ams.ams_51_23.

References
1.
Aggarwal S, Singh M, Modi P, Walia E, Aggarwal R . Comparison of 3D plate and locking plate in treatment of mandibular fracture-a clinical study. Oral Maxillofac Surg. 2017; 21(4):383-390. DOI: 10.1007/s10006-017-0642-1. View

2.
Sadhwani B, Anchlia S . Conventional 2.0 mm miniplates versus 3-D plates in mandibular fractures. Ann Maxillofac Surg. 2013; 3(2):154-9. PMC: 3814664. DOI: 10.4103/2231-0746.119231. View

3.
Mittal G, Dubbudu R, Cariappa K . Three dimensional titanium mini plates in oral & maxillofacial surgery: a prospective clinical trial. J Maxillofac Oral Surg. 2013; 11(2):152-9. PMC: 3386418. DOI: 10.1007/s12663-011-0267-0. View

4.
Bouloux G, Chen S, Threadgill J . Small and large titanium plates are equally effective for treating mandible fractures. J Oral Maxillofac Surg. 2012; 70(7):1613-21. DOI: 10.1016/j.joms.2012.02.029. View

5.
Farmand M, Dupoirieux L . [The value of 3-dimensional plates in maxillofacial surgery]. Rev Stomatol Chir Maxillofac. 1992; 93(6):353-7. View