» Articles » PMID: 33858987

A Guideline to Limit Indoor Airborne Transmission of COVID-19

Overview
Specialty Science
Date 2021 Apr 16
PMID 33858987
Citations 161
Authors
Affiliations
Soon will be listed here.
Abstract

The current revival of the American economy is being predicated on social distancing, specifically the Six-Foot Rule, a guideline that offers little protection from pathogen-bearing aerosol droplets sufficiently small to be continuously mixed through an indoor space. The importance of airborne transmission of COVID-19 is now widely recognized. While tools for risk assessment have recently been developed, no safety guideline has been proposed to protect against it. We here build on models of airborne disease transmission in order to derive an indoor safety guideline that would impose an upper bound on the "cumulative exposure time," the product of the number of occupants and their time in an enclosed space. We demonstrate how this bound depends on the rates of ventilation and air filtration, dimensions of the room, breathing rate, respiratory activity and face mask use of its occupants, and infectiousness of the respiratory aerosols. By synthesizing available data from the best-characterized indoor spreading events with respiratory drop size distributions, we estimate an infectious dose on the order of 10 aerosol-borne virions. The new virus (severe acute respiratory syndrome coronavirus 2 [SARS-CoV-2]) is thus inferred to be an order of magnitude more infectious than its forerunner (SARS-CoV), consistent with the pandemic status achieved by COVID-19. Case studies are presented for classrooms and nursing homes, and a spreadsheet and online app are provided to facilitate use of our guideline. Implications for contact tracing and quarantining are considered, and appropriate caveats enumerated. Particular consideration is given to respiratory jets, which may substantially elevate risk when face masks are not worn.

Citing Articles

CO2 and aerosol concentration during manual and mechanical chest compression while cardiopulmonary resuscitation.

Heymer J, Dengler F, Hein A, Krohn A, Jaki C, Echterdiek F Medicine (Baltimore). 2025; 104(7):e41528.

PMID: 39960930 PMC: 11835093. DOI: 10.1097/MD.0000000000041528.


Interactive Simulation of Nonpharmaceutical Interventions of Airborne Disease Transmission in Office Settings.

Zimmerman T, Sharma N, Bulu H, Burrowes V, Beymer D, Mukherjee V Int J Environ Res Public Health. 2024; 21(11).

PMID: 39595680 PMC: 11593966. DOI: 10.3390/ijerph21111413.


Resolving the Loss of Intermediate-Size Speech Aerosols in Funnel-Guided Particle Counting Measurement.

Kakeshpour T, Bax A Atmosphere (Basel). 2024; 15(5).

PMID: 39574922 PMC: 11581197. DOI: 10.3390/atmos15050570.


Comparative analysis of personal protective equipment nonadherence detection: computer vision versus human observers.

Kim M, Park B, Sippel G, Mun A, Yang W, McCarthy K J Am Med Inform Assoc. 2024; 32(1):163-171.

PMID: 39401253 PMC: 11648733. DOI: 10.1093/jamia/ocae262.


Beyond six feet: The collective behavior of social distancing.

Wu Z PLoS One. 2024; 19(9):e0293489.

PMID: 39269926 PMC: 11398703. DOI: 10.1371/journal.pone.0293489.


References
1.
Bhagat R, Davies Wykes M, Dalziel S, Linden P . Effects of ventilation on the indoor spread of COVID-19. J Fluid Mech. 2021; 903:F1. PMC: 7520710. DOI: 10.1017/jfm.2020.720. View

2.
Watanabe T, Bartrand T, Weir M, Omura T, Haas C . Development of a dose-response model for SARS coronavirus. Risk Anal. 2010; 30(7):1129-38. PMC: 7169223. DOI: 10.1111/j.1539-6924.2010.01427.x. View

3.
Buonanno G, Stabile L, Morawska L . Estimation of airborne viral emission: Quanta emission rate of SARS-CoV-2 for infection risk assessment. Environ Int. 2020; 141:105794. PMC: 7211635. DOI: 10.1016/j.envint.2020.105794. View

4.
Buonanno G, Morawska L, Stabile L . Quantitative assessment of the risk of airborne transmission of SARS-CoV-2 infection: Prospective and retrospective applications. Environ Int. 2020; 145:106112. PMC: 7474922. DOI: 10.1016/j.envint.2020.106112. View

5.
Cheng K, Acevedo-Bolton V, Jiang R, Klepeis N, Ott W, Fringer O . Modeling exposure close to air pollution sources in naturally ventilated residences: association of turbulent diffusion coefficient with air change rate. Environ Sci Technol. 2011; 45(9):4016-22. DOI: 10.1021/es103080p. View