» Articles » PMID: 33799654

Study on Characteristics of Particulate Matter Resuspension in School Classroom Through Experiments Using a Simulation Chamber: Influence of Humidity

Overview
Publisher MDPI
Date 2021 Apr 3
PMID 33799654
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

Resuspension of particulate matter (PM) in classrooms, which increases the risk of negative impact on student health from exposure to PM, is influenced by humidity level in the indoor environment. The goal of this study is to investigate the properties of PM resuspension in accordance with relative humidity through classroom test chamber experiments. In actual classrooms, it is challenging to control factors influencing resuspension. Therefore, the classroom chamber that reflects the environment of elementary school classroom (e.g., structure, floor material) is used in this study. The humidity of the classroom chamber is adjusted to 35%, 55%, 75%, and 85% by placing it inside a real-size environmental chamber, which allows artificial control of climatic conditions. At the respective humidity conditions, PM resuspension concentration and resuspension factor caused by occupant walking across the classroom chamber are analyzed. The results show that both of the resuspension concentration and resuspension factor reveal a linear negative correlation to humidity increase. Furthermore, coefficient of determination (R) indicating goodness-of-fit of the linear regression model between the resuspension concentration and humidity is 0.88 for PM and 0.93 for PM. It implies that accuracy of the regression model for estimating PM and PM resuspension concentrations is 88% and 93%, respectively.

Citing Articles

Quantitative evaluation of the impact of indoor relative humidity on deposition of aerosols generated during tooth grinding in a real-world clinical setting.

Li Y, Li J, Hu J, Yu X, Li Z, Cao J Clin Oral Investig. 2024; 28(5):292.

PMID: 38693418 DOI: 10.1007/s00784-024-05683-6.


Particulate Matter Concentration in Selected Facilities as an Indicator of Exposure to Their Service Activities.

Rogula-Kopiec P, Rogula-Kozlowska W, Majewski G Int J Environ Res Public Health. 2022; 19(16).

PMID: 36011921 PMC: 9407963. DOI: 10.3390/ijerph191610289.


Screening of Particulate Matter Reduction Ability of 21 Indigenous Korean Evergreen Species for Indoor Use.

Jang B, Park K, Lee S, Lee H, Yeon S, Ji B Int J Environ Res Public Health. 2021; 18(18).

PMID: 34574725 PMC: 8466017. DOI: 10.3390/ijerph18189803.

References
1.
Qian J, Ferro A, Fowler K . Estimating the resuspension rate and residence time of indoor particles. J Air Waste Manag Assoc. 2008; 58(4):502-16. DOI: 10.3155/1047-3289.58.4.502. View

2.
Tian Y, Sul K, Qian J, Mondal S, Ferro A . A comparative study of walking-induced dust resuspension using a consistent test mechanism. Indoor Air. 2014; 24(6):592-603. DOI: 10.1111/ina.12107. View

3.
Dockery D, Pope 3rd C . Acute respiratory effects of particulate air pollution. Annu Rev Public Health. 1994; 15:107-32. DOI: 10.1146/annurev.pu.15.050194.000543. View

4.
McDonagh A, Byrne M . The influence of human physical activity and contaminated clothing type on particle resuspension. J Environ Radioact. 2013; 127:119-26. DOI: 10.1016/j.jenvrad.2013.10.012. View

5.
Nguyen J, Schwartz J, Dockery D . The relationship between indoor and outdoor temperature, apparent temperature, relative humidity, and absolute humidity. Indoor Air. 2013; 24(1):103-12. PMC: 3791146. DOI: 10.1111/ina.12052. View