High-efficiency High-voltage Class F Amplifier for High-frequency Wireless Ultrasound Systems

Overview
Journal PLoS One
Date 2021 Mar 29
PMID 33780492
Citations 24
Authors
Affiliations
Soon will be listed here.
Abstract

This paper presents a novel amplifier that satisfies both low distortion and high efficiency for high-frequency wireless ultrasound systems with limited battery life and size. While increasing the amplifier efficiency helps to address the problems for wireless ultrasound systems, it can cause signal distortion owing to harmonic components. Therefore, a new type of class F amplifier is designed to achieve high efficiency and low distortion. In the amplifier, the resonant circuit at each stage controls the harmonic components to reduce distortion and improve efficiency. Transformers with a large shunt resistor are also helpful to reduce the remaining noise in the input signal. The proposed class F amplifier is tested using simulations, and the voltage and current waveforms are analyzed to achieve correct operation with adequate efficiency and distortion. The measured performance of the class F amplifier has a gain of 23.2 dB and a power added efficiency (PAE) of 88.9% at 25 MHz. The measured DC current is 121 mA with a variance of less than 1% when the PA is operating. We measured the received echo signal through the pulse-echo response using a 25-MHz transducer owing to the compatibility of the designed class F amplifier with high- frequency transducers. The measured total harmonic distortion (THD) of the echo signal was obtained as 4.5% with a slightly low ring-down. The results show that the low THD and high PAE of the new high-efficiency and high-voltage amplifier may increase battery life and reduce the cooling fan size, thus providing a suitable environment for high-frequency wireless ultrasound systems.

Citing Articles

Novel stability approach using Routh-Hurwitz criterion for brain computer interface applications.

Heo S, Choi H, Yang Y Technol Health Care. 2024; 32(S1):17-25.

PMID: 38669494 PMC: 11191471. DOI: 10.3233/THC-248002.


Design of Preamplifier for Ultrasound Transducers.

Choi H Sensors (Basel). 2024; 24(3).

PMID: 38339502 PMC: 10856992. DOI: 10.3390/s24030786.


Power Amplifier Design for Ultrasound Applications.

Choi H Micromachines (Basel). 2023; 14(7).

PMID: 37512653 PMC: 10383379. DOI: 10.3390/mi14071342.


Point-of-Care Thoracic Ultrasound in Children: New Advances in Pediatric Emergency Setting.

Bloise S, Marcellino A, Sanseviero M, Martucci V, Testa A, Leone R Diagnostics (Basel). 2023; 13(10).

PMID: 37238249 PMC: 10217038. DOI: 10.3390/diagnostics13101765.


Harmonic-Reduced Bias Circuit for Ultrasound Transducers.

Choi H Sensors (Basel). 2023; 23(9).

PMID: 37177641 PMC: 10181787. DOI: 10.3390/s23094438.


References
1.
Michailovich O, Tannenbaum A . Despeckling of medical ultrasound images. IEEE Trans Ultrason Ferroelectr Freq Control. 2006; 53(1):64-78. PMC: 3639001. DOI: 10.1109/tuffc.2006.1588392. View

2.
ODonnell M . Coded excitation system for improving the penetration of real-time phased-array imaging systems. IEEE Trans Ultrason Ferroelectr Freq Control. 1992; 39(3):341-51. DOI: 10.1109/58.143168. View

3.
Goldberg B . International arena of ultrasound education. J Ultrasound Med. 2003; 22(6):549-51. DOI: 10.7863/jum.2003.22.6.549. View

4.
Choi H . Prelinearized Class-B Power Amplifier for Piezoelectric Transducers and Portable Ultrasound Systems. Sensors (Basel). 2019; 19(2). PMC: 6359466. DOI: 10.3390/s19020287. View

5.
Choi H, Li X, Lau S, Hu C, Zhou Q, Shung K . Development of integrated preamplifier for high-frequency ultrasonic transducers and low-power handheld receiver. IEEE Trans Ultrason Ferroelectr Freq Control. 2013; 58(12):2646-58. PMC: 3589742. DOI: 10.1109/TUFFC.2011.2127. View