Multifunctional and low-cost electrode materials are desirable for the next-generation sensors and energy storage applications. This paper reports the use of pencil graphite as an electrode for dual applications that include the detection of free residual chlorine using electro-oxidation process and as an electrochemical energy storage cathode. The pencil graphite is transferred to cellulose paper by drawing ten times and applied for the detection of free residual chlorine, which shows a sensitivity of 27 μA mM-1 cm-2 with a limit of detection of 88.9 μM and linearity up to 7 mM. The sample matrix effect study for the commonly interfering ions such as NO3-, SO42-, CO32-, Cl-, HCO3- shows minimal impact on free residual chlorine detection. Pencil graphite then used after cyclic voltammogram treatment as a cathode in the aqueous Zn/Al-ion battery, showing an average discharge potential plateau of ~1.1 V, with a specific cathode capacity of ~54.1 mAh g-1 at a current of 55 mA g-1. It maintains ~95.8% of its initial efficiency after 100 cycles. Results obtained from the density functional theory calculation is consistent with the electro-oxidation process involved in the detection of free residual chlorine, as well as intercalation and de-intercalation behavior of Al3+ into the graphite layers of Zn/Al-ion battery. Therefore, pencil graphite due to its excellent electro-oxidation and conducting properties, can be successfully implemented as low cost, disposable and green material for both sensor and energy-storage applications.

Citing Articles

Simple and promising paper-based electrochemical platform for serological detection of American tegumentary leishmaniasis.

Barraza D, Nanni P, Bracamonte M, Chaile R, Goy C, Acuna L Mem Inst Oswaldo Cruz. 2024; 119:e230149.

PMID: 38359306 PMC: 10868376. DOI: 10.1590/0074-02760230149.


Development of a Redox-Polymer-Based Electrochemical Glucose Biosensor Suitable for Integration in Microfluidic 3D Cell Culture Systems.

Navarro-Nateras L, Diaz-Gonzalez J, Aguas-Chantes D, Coria-Oriundo L, Battaglini F, Ventura-Gallegos J Biosensors (Basel). 2023; 13(6).

PMID: 37366947 PMC: 10295976. DOI: 10.3390/bios13060582.


Fabrication of a Disposable Amperometric Sensor for the Determination of Nitrite in Food.

Liu C, Chen D, Zhu C, Liu X, Wang Y, Lu Y Micromachines (Basel). 2023; 14(3).

PMID: 36985095 PMC: 10056392. DOI: 10.3390/mi14030687.


Detection of free chlorine in water using graphene-like carbon based chemiresistive sensors.

Zubiarrain-Laserna A, Angizi S, Akbar M, Divigalpitiya R, Selvaganapathy P, Kruse P RSC Adv. 2022; 12(4):2485-2496.

PMID: 35425275 PMC: 8979178. DOI: 10.1039/d1ra08264g.

References
1.
Padmanathan N, Shao H, Razeeb K . Multifunctional Nickel Phosphate Nano/Microflakes 3D Electrode for Electrochemical Energy Storage, Nonenzymatic Glucose, and Sweat pH Sensors. ACS Appl Mater Interfaces. 2018; 10(10):8599-8610. DOI: 10.1021/acsami.7b17187. View

2.
Wang J . Electrochemical glucose biosensors. Chem Rev. 2007; 108(2):814-25. DOI: 10.1021/cr068123a. View

3.
Jin J, Suzuki Y, Ishikawa N, Takeuchi T . A miniaturized FIA system for the determination of residual chlorine in environmental water samples. Anal Sci. 2004; 20(1):205-7. DOI: 10.2116/analsci.20.205. View

4.
Tang W, Hou Y, Wang F, Liu L, Wu Y, Zhu K . LiMn2O4 nanotube as cathode material of second-level charge capability for aqueous rechargeable batteries. Nano Lett. 2013; 13(5):2036-40. DOI: 10.1021/nl400199r. View

5.
Jamal M, Hasan M, Mathewson A, Razeeb K . Disposable sensor based on enzyme-free Ni nanowire array electrode to detect glutamate. Biosens Bioelectron. 2012; 40(1):213-8. DOI: 10.1016/j.bios.2012.07.024. View