» Articles » PMID: 33672382

Ball Versus Locator Attachments: A Retrospective Study on Prosthetic Maintenance and Effect on Oral-Health-Related Quality of Life

Overview
Publisher MDPI
Date 2021 Mar 6
PMID 33672382
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Locator and ball attachments are well-established systems to attach overdentures to two inter-foraminal implants. This study aimed to evaluate differences between the two systems regarding prosthetic maintenance and patients' oral-health-related quality of life (OHRQoL). Dental records of patients with a mandibular implant-retained overdenture were retrospectively analyzed. Prosthetic maintenance measures involving the denture suprastructure and attachment matrix and patrix were analyzed. Furthermore, the Oral Health Impact Profile-G14 (OHIP-G14) was used to evaluate OHRQoL. Results were analyzed by means of Kaplan-Meier analysis and Student's - and log-rank tests. The records of 122 patients were evaluated. Kaplan-Meier survival analysis revealed a significant difference between ball attachments (Group B; patients = 47) and Locator attachments (Group L; patients = 75) regarding the occurrence of denture fractures ( < 0.001) and events affecting the matrix ( = 0.028) and patrix ( = 0.030). Group L had a significantly lower total OHIP-G14 score than Group B ( = 0.002). The most common maintenance events were matrix-related and denture relining for both attachment systems. Group B required more maintenance measures than Group L. Moreover, patients in Group L had better OHRQoL than patients in Group B.

Citing Articles

Stress Distribution Pattern in Mandibular Overdenture Designs Supported by Three Dental Implants: A 3D Finite Element Analysis.

Aminianpour N, Alikhasi M, Kasari M, Yousefi H, Siadat H Clin Exp Dent Res. 2025; 11(1):e70060.

PMID: 40025660 PMC: 11872805. DOI: 10.1002/cre2.70060.


Assessment of a novel electrochemically deposited smart bioactive trabecular coating (SBTC®): a randomized controlled clinical trial.

Antal M, Kiscsatari R, Braunitzer G, Piffko J, Varga E, Eliaz N Head Face Med. 2024; 20(1):24.

PMID: 38627712 PMC: 11022491. DOI: 10.1186/s13005-024-00426-0.


Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures.

Avukat E, Akay C, Mumcu E J Adv Prosthodont. 2023; 15(4):214-226.

PMID: 37662854 PMC: 10471504. DOI: 10.4047/jap.2023.15.4.214.


Immediate versus Delayed Attachment Incorporation Impact on Prosthetic Aftercare among Mandibular Implant-Supported Overdenture Wearers.

Zenziper E, Rosner O, Ghelfan O, Nissan J, Blumer S, Ben-Izhack G J Clin Med. 2022; 11(12).

PMID: 35743594 PMC: 9224628. DOI: 10.3390/jcm11123524.


Oral health-related quality of life of patients rehabilitated with fixed and removable implant-supported dental prostheses.

Duong H, Roccuzzo A, Stahli A, Salvi G, Lang N, Sculean A Periodontol 2000. 2022; 88(1):201-237.

PMID: 35103325 PMC: 9304161. DOI: 10.1111/prd.12419.


References
1.
Fouda S, Al-Attar M, I Virtanen J, Raustia A . Effect of Patient's Personality on Satisfaction with Their Present Complete Denture and after Increasing the Occlusal Vertical Dimension: A Study of Edentulous Egyptian Patients. Int J Dent. 2014; 2014:635943. PMC: 4119631. DOI: 10.1155/2014/635943. View

2.
Kuoppala R, Napankangas R, Raustia A . Quality of Life of Patients Treated With Implant-Supported Mandibular Overdentures Evaluated With the Oral Health Impact Profile (OHIP-14): a Survey of 58 Patients. J Oral Maxillofac Res. 2014; 4(2):e4. PMC: 3886109. DOI: 10.5037/jomr.2013.4204. View

3.
Gotfredsen K, Holm B . Implant-supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5-year study. Int J Prosthodont. 2001; 13(2):125-30. View

4.
Yabul A, Dayan C, Geckili O, Bilhan H, Tuncer N . Evaluation of volumetric wear of abutments on the retention loss of ball attachment systems in implant-retained overdentures: An in vitro study. Clin Implant Dent Relat Res. 2018; 20(5):778-784. DOI: 10.1111/cid.12644. View

5.
Kern J, Kern T, Wolfart S, Heussen N . A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss. Clin Oral Implants Res. 2015; 27(2):174-95. PMC: 5024059. DOI: 10.1111/clr.12531. View